NOTICE
When the worm-screws are tightened, the springs in the tensioner
are compressed. To avoid the strap becoming lose or over-tightened
when the pipe temperature changes, it is important that the spring is
set to the correct tension. Do not over-tighten the worm-screws.
7. Ensure the metal plate is centered through the plus (+) shaped cut-
outs on both sides of the tensioner. If it is not centered, either loosen
or tighten the worm-screws on either side until they do align. Ensure
the sensor is firmly fixed and sitting perpendicular to the pipe as
shown in
8. When all the adjustments have been completed, make a final check
of the waveform quality (refer to
•
If it is poor, slacken off the strap and adjust the sensor position
before returning to
.
•
If the waveform quality is good, continue to
9. If there is an excessive length of spare strap, you may cut off the
excess length.
10. Click the
Complete
button.
Verify the
Install State
is
Off
and
Installed
is selected in the footer of
the application.
Figure 3-6: Installation Tool Screen: Fully Provisioned
11. Remove the CC21 and fit the power module, tightening the two
power module retaining bolts. Refer to the
Module for Wireless Corrosion Transmitter Quick Start Guide
.
When the power module is fitted, the sensor automatically restarts
and tries to join the
Wireless
HART
®
Gateway. In a large network of
100 sensors this can often take two hours, and sometimes up to six
hours.
Quick Start Guide
January 2022
22
Emerson.com/Rosemount
Содержание Rosemount ET310
Страница 4: ...Quick Start Guide January 2022 4 Emerson com Rosemount ...
Страница 42: ...6 14 China RoHS Quick Start Guide January 2022 42 Emerson com Rosemount ...
Страница 44: ...Quick Start Guide January 2022 44 Emerson com Rosemount ...
Страница 50: ...Quick Start Guide January 2022 50 Emerson com Rosemount ...
Страница 51: ...January 2022 Quick Start Guide Quick Start Guide 51 ...