Table A-5: Detector screen fields
(continued)
Detector Screen
G1 Board
G2 Board
Field Names
Flame ionization
detector (FID)
Flame
photometric
detector (FPD)
FID
FPD
Flame Ignition
Selectable
Blank
Selectable
Selectable
Ignition Attempts
Editable
Blank
Editable
Editable
Wait Time Bet Tries
Editable
Blank
Editable
Editable
Igniter On Duration
Editable
Blank
Editable
Editable
Flame On Sense Temp
Editable
Blank
Editable
Editable
Flame Out Sense Temp
Editable
Blank
Editable
Editable
FPD Flame Status DI
Blank
Selectable
Blank
Blank
Scaling Factor
Read only
Read only
Read only
Blank
Flame Temp
Read only
Blank
Read only
Read only
The
Detector
screen field label names and their respective field statuses are described as
editable or non-editable depending on G1/G2 board types.
When you select one of the buttons on G1 boards (for example,
Auto-zero
), then since FID
and µFPD are both enabled for Auto-zero, when that button is selected a combo box
displays for you to select either FID or µFPD detector (if both detector types are configured
with the gas chromatograph [GC]). After selecting one of the detectors, the Auto-zero
event is triggered for that detector.
For G2 boards, since the µFPD is disabled for Auto-zero no combo box displays for you to
select the detector. Only one detector is a valid selection for Auto-zero in the available
detectors on that GC, so the
Auto-zero
selection triggers the event for the FID detector. If
the button option is valid for more than one detector type, only then does the combo box
display. If only one detector type is valid for that specific button, then the combo box does
not display and the selection triggers that specific event on the only workable detector.
Table A-6: Detector screen Auto-zero buttons
Button Name
G1 Board
G2 Board
FID
FPD
FID
FPD
Auto-Zero
Enabled
Enabled
Enabled
Disabled
Reference Manual
Local operator interface (LOI)
2-3-9000-744
June 2022
Rosemount 700XA
237
Содержание Rosemount 700XA
Страница 1: ...Reference Manual 2 3 9000 744 Rev L June 2022 Rosemount 700XA Gas Chromatograph ...
Страница 6: ...TxD TD or Sout Transmit data or signal out 6 ...
Страница 30: ...Overview Reference Manual June 2022 2 3 9000 744 30 Emerson com Rosemount ...
Страница 100: ...Installation and start up Reference Manual June 2022 2 3 9000 744 100 Emerson com Rosemount ...
Страница 117: ...Figure 5 10 LSIV exploded view Reference Manual Operation and maintenance 2 3 9000 744 June 2022 Rosemount 700XA 117 ...
Страница 182: ...Operation and maintenance Reference Manual June 2022 2 3 9000 744 182 Emerson com Rosemount ...
Страница 223: ...Figure A 19 Chromatogram menu Reference Manual Local operator interface LOI 2 3 9000 744 June 2022 Rosemount 700XA 223 ...
Страница 262: ...Local operator interface LOI Reference Manual June 2022 2 3 9000 744 262 Emerson com Rosemount ...
Страница 270: ...Micro flame photometric detector µFPD Reference Manual June 2022 2 3 9000 744 270 Emerson com Rosemount ...
Страница 278: ...Pre defined Modbus map files Reference Manual June 2022 2 3 9000 744 278 Emerson com Rosemount ...
Страница 280: ......
Страница 281: ......
Страница 282: ......
Страница 293: ......