22
‐
Parameter
Name
Setting range
Min.
unit
Default
Mod.
pulse counted
for door
position at
fault time
F9.12
High digit of
OD times
0 ~ 9999 (×10000)
1
0
*
F9.13
Low digit of
OD times
0 ~ 9999
1
0
*
F9.14
High digit of
CD times
0 ~ 9999 (×10000)
1
0
*
F9.15
Low digit of
CD times
0 ~ 9999
1
0
*
F9.16
Total
operation time
0 ~ 65535 hours (max.)
1 hour
0
*
F9.17
Total running
time
0 ~ 65535 hours (max)
1 hour
0
*
F9.18
Parameter
initialization
0: no operation
1: Clear the record
2: Load defaults
3 ~ 100: reserved
1 0 ×
F9.19
Software
version No.
1.00 ~ 99.99
0.01
Actual version
No.
-
F9.20
Product
configuration
No.
3200 ~ 3299
1
Actual
configuration
No.
-
F9.21
Heatsink
temperature
0 ~ 100°C
1
0
*
F9.22
Relay output
polarity
selection
0: relays PA1/PC1 and PA2/PC2
serve as output NC relays
1: relays PA1/PC1 and PA2/PC2
serve as output NO relays
0 1
×
8.
Troubleshooting
EV3200
can
detect
19
types
of
faults.
When
fault
occurs,
you
can
get
the
information
of
fault
codes,
DC
bus
voltage,
output
current,
operating
frequency
and
terminal
status
by
reviewing
the
values
of
F9.02
~
F9.09.
You
can
check
the
faults
according
to
the
following
table
and
note
down
the
fault
phenomena
before
seeking
technical
service.
Fault
code
Fault type
Possible cause
Action to take
E001
Over-current in
Acc process
1) Acc time is too short.
2) Restart the motor in motion when
momentary stop occurs.
1) Prolong the Acc time;
2) Start the motor after it
stops.