11
‐
Frequency
F2.04
Time
F2.02
F2.08
F2.00
F2.11
F2.10
F2.03
F2.07
CD
CD speed
decrease signal
CD position
limiting signal
ON
OFF
ON
OFF
ON
OFF
CD
operation
curve
for
speed
control
7.Parameter
Table
Set
F9.18
to
3
to
restore
the
factory
settings.
7.1
Basic
Operation
Parameters
F0
Parameter
Name
Setting range
Min.
unit
Default Mod.
F0.00
User
password
0 ~ 9999 (0000 means no password)
1
0
○
F0.01
Control mode
0: speed control
1: distance control 1
2: distance control 2
3: distance control 3
1 1 ×
F0.02
Control
command
selection
0: keypad control mode of general-purpose
inverter
1: keypad control mode of the inverter used for
controlling elevator door
2: terminal control mode of the inverter used for
controlling elevator door
3: communication control mode of the inverter
used for controlling elevator door (reserved)
4: Auto-demo mode
5: terminal control mode of general-purpose
inverter
6: reserved
7: communication control mode of
general-purpose inverter (reserved)
1 2 ×
www.novaelevator.com