16
‐
Parameter
Name
Setting range
Min.
unit
Defa
ult
Mo
d.
F5.00
F5.01
F5.02
F5.03
F5.04
Function selection
for control
terminals X1 ~
X5
0: No functions (can be set repetitively)
1: External reset (RESET) signal input
2: Normally open input contacts for light
curtain signal
3: Normally closed input contacts for light
curtain signal
4: Normally open input contacts for safety
edge
5: Normally closed input contacts for safety
edge
6: Normally open input for OD position
limiting
7: Normally closed input for OD position
limiting
8: Normally open input for CD position
limiting
9: Normally closed input for CD position
limiting
10: Normally open input contacts for OD
speed decrease
11: Normally closed input contacts for OD
speed decrease
12: Normally open input contacts for CD
speed decrease
13: Normally closd input contacts for CD
speed decrease
14: Terminal for inputting OD prohibition
signal
15: Terminal for inputting torque
maintaining prohibition signal
16: Low speed OD/CD enable signal input
17: Normally open input for lock signal
18: Normally closed input for lock signal
19: Emergency Firemen Service (EFS)
function input
20: Rush hour operation enable signal input
21: Operation enable signal input (valid for
X5 only)
22: Door width auto-learning command
input (valid for X5 only)
1 0
×