Specifications
Working
temperature
-10°C ~ + 40°C, temperature change less than 0.5°C
/minute
Must be derated above 40°C: The output current must
be derated 2% for every rise of 1°C.
Max temperature: 50°C
Humidity
Less than 95%RH, no condensation
Vibration
3.5mm (2 ~ 9Hz), 10m/s
2
(9 ~ 200Hz), 15m/s
2
(200 ~
500Hz)
Storage
temperature
-40°C ~ + 70°C
Protection IP21
Structure
Cooling
Forced air cooling (EV3200-2S0004A and
EV3200-2S0004S)
Natural air cooling (EV3200-2S0002A and
EV3200-2S0002S)
2.
Operation
LED
Programming key
Shift key
OD key
CD key
Digit modification key
Function and data
switchover key
Save key
Stop key
Reset key
Key
Name
Function
Programming
Switches between stopping status/operating status and
programming state.
Function /Data
Select data monitor mode and data input confirmation
Up Increase
Down Decrease