13
‐
Parameter
Name
Setting range
Min.
unit
Default Mod.
F2.00
CD start creep time for speed
control
10 ~ 9999ms
1ms
500ms
○
F2.01
CD start creep distance
0 ~ 30.0% (door width)
0%
0%
○
F2.02
CD start creep speed
1.00 ~ 25.00Hz
0.01Hz 1.00Hz
○
F2.03
CD Acc time
0.1 ~ 3600s
0.1s
3s
○
F2.04
CD reference frequency
0.00 ~ F0.04 max frequency 0.01Hz 10.00Hz
○
F2.05
Rush hour operation CD speed 0.00 ~ F0.04 max frequency 0.01Hz 10.00Hz
○
F2.06
CD speed decrease point in
distance control
pulse number (door width)
1
1000
○
F2.07
CD Dec time
0.1 ~ 3600s
0.1s
3s
○
F2.08
CD ending creep speed
0 ~ 15.00Hz
0.01Hz 2Hz
○
F2.09
CD position limit in distance
control
1 ~ 9999 (pulse number)
1
250
○
F2.10
Swithcing point of CD
complete maintainging torque
0.0% ~ 100.0% (motor rated
torque)
0.1% 40.0%
○
F2.11
CD complete maintainging
torque
0.0% ~ 100.0% (motor rated
torque)
0.1% 40.0%
○
F2.12
CD speed for EFS
5.00 ~ 25.00Hz
0.01Hz 10.00Hz
○
F2.13
CD operation curve selection in
distance control
0: selecting manually preset
curve;
1: selecting optimum curve
by auto-learning
1 0 ×
F2.14
CD optimum curve correction
factor
3.0% ~ 15.0% (door width)
0.1% 10.0%
○
F2.15
Distance control CD door
locking point
000 ~ 9999
1
362
○
F2.16
CD speed after door locking
point
0.00 ~ 20.00Hz
0.01Hz 1.80Hz
○
7.4
Enhanced
Function
Parameters
F3
Parameter
Name
Setting range
Min.
unit
Default Mod.
F3.00
INI operation speed
0.00 ~ 20.00Hz
0.01Hz 5.00Hz
○
F3.01
OD time limit
0 ~ 3600s
1s
300s
○
F3.02
CD time limit
0 ~ 3600s
1s
300s
○
F3.03
Slow speed operation time limit 0 ~ 3600s
1s
400s
○
F3.04
Delay time for external OD
command
0 ~ 9999S
1s
1200s
○
F3.05
Delay time for external CD
command
0 ~ 9999S
1s
600s
○
www.novaelevator.com