Items
Subitems
Specifications
Auto tuning of
motor's
parameters
Purpose of auto tuning function of inverter is to obtain the
motor's parameters automatically, and these parameters will be
saved automatically after the tuning process is over
Speed-adjusting
range
Under rated load condition, 1:100 for vector control with speed
sensor; 1:50 for sensorless vector control
OD,
CDcontrol
command
input
Terminal control mode; keypad control mode;
communication control mode (reserved)
Frequency
setting
Set the frequency via keypad; communication control
mode (reserved)
Multi-function
terminal input
signal
External reset signal, light curtain signal, safety edge
signal, OD position limiting signal, CD position
limiting signal, OD speed decrease signal, CD speed
decrease signal, OD prohibition signal, torque
maintaining signal, slow OD and CD signals, lock
signal, emergency firemen service (EFS) signal, rush
hour operation enable operation, operation enable
signal, auto-learning command signal
Operation
functions
Output signal
3 relay-output: 250Vac/2A (cos
Φ
=1), 250Vac/1A
(cos
Φ
=0.4), 30Vdc/1A
Display
4-digit LED
display
Running frequency, reference frequency, output
voltage, output current, output torque, DC bus voltage,
status of input terminals, status of output terminals,
door-operating position (pulse number)
Protection functions
Over current protection, over voltage protection, low
voltage protection, over heat protection, overload
protection, output phase failure protection, motor
protection, motor tuning error alarm, parameter
setting error alarm, door width auto-learning error
alarm, OD/CD error alarm, pulse generator (PG) error
alarm, current detection circuit fault alarm, EEPROM
read/write error alarm, over-speed protection
Application
environment
Inside, free from direct sunlight, dust, corrosive gas,
combustible gas, oil mist, steam, water drop, and so on
Environment
Altitude
Lower than 1000m. Max altitude: 3000m (deration
curve should be observed at 1000m ~ 3000m: derated
10% for every rise of 100m)