![Emerson EV3200-2S0002A Скачать руководство пользователя страница 17](http://html.mh-extra.com/html/emerson/ev3200-2s0002a/ev3200-2s0002a_manual_103367017.webp)
‐
17
‐
Parameter
Name
Setting range
Min.
unit
Defa
ult
Mo
d.
F5.05
Function of
programmable
relay output
PA1/PC1
0
F5.06
Function of
programmable
relay output
PA2/PC2
1
F5.07
Function of
programmable
relay output
PA3/PB3/PC3
0: Output signal 0 for complete OD
(immediately output upon position limiting)
1: Output signal 0 for complete CD
(immediately output upon position limiting)
2: Output signal 1 for complete OD
(output after position limiting and lock)
3: Output signal 1 for complete CD
(output after position limiting and lock)
4: Output signal 2 for complete OD
(output after position limiting, lock, and
door lock invalid)
5: Output signal 2 for complete CD
(output after position limiting, lock, and
door lock valid)
6: Fault relay output 1
(not including POFF status)
7: Fault relay output 2
(including POFF status)
8: Safety edge lift signal output
9: Lock signal synchronous output
10: Re-opening signal output
11: Obstruction signal output
1
6
×
7.7
Motor
Parameters
F6
Parameter
Name
Setting range
Min.
unit
Default
Mod.
F6.00
Motor type selection
0: asynchronous motor;
1: synchronous motor
1 0
×
F6.01
Motor rated power
0 ~ 500W
1W
250
×
F6.02
Motor rated voltage
0 ~ 250V
1V
220
×
F6.03
Motor rated current
0.10 ~ 9.90A
0.01A
1.1
×
F6.04
Motor max allowable
operation current
100.0% ~ 200.0% (motor
rated current)
0.1% 150.0% ×
F6.05
Motor rated frequency 1.00Hz ~ 128.0Hz
0.01Hz
50.00Hz
×
F6.06
Motor rated spinning
speed
1 ~ 9999rpm
1r/min
900
×
F6.07 Motor
tuning
0: disable 1:
enable
1 0
×
F6.08
Stator resistance
00.00 ~ 99.99ohm
0.01ohm
24.71
×
F6.09
Stator inductance
0 ~ 9999mH
1mH
998
×
F6.10
Rotor resistance
00.00 ~ 99.99ohm
0.01ohm
19.37
×
F6.11
Rotor inductance
0 ~ 9999mH
1mH
998
×
F6.12
Mutual inductance
0 ~ 9999mH
1mH
921
×
www.novaelevator.com