18
‐
Parameter
Name
Setting range
Min.
unit
Default
Mod.
F6.13
Exciting current with
no load
0.00 ~ 99.99A
0.01A
0.39
×
7.8
Vector
Control
Parameters
F7
Parameter
Name
Setting range
Min. unit
Default
Mod.
F7.00
ASR proportional gain
1
0.000 ~ 6.000
0.001
0.600
×
F7.01
ASR integral time 1
0 (integral function
disabled), 0.032-32.00s
0.001s 1.000 ×
F7.02
ASR proportional gain
2
0.000 ~ 6.000
0.001
0.600
×
F7.03
ASR integral time 2
0 (integral function
disabled), 0.032-32.00s
0.001s 1.000 ×
F7.04
ASR changing
frequency
0.00 ~ 50.0Hz
0.01Hz
5.00
×
F7.05
Slip compensation gain
0 (reserved), 50.0 ~ 250.0%
(for accounting the slip
value)
0.1% 100.0% ×
F7.06 Motoring
torque
limit
0.0 ~ 200.0% (inverter rated
current)
0.1% 100.0% ×
F7.07 Braking
torque
limit
0.0 ~ 200.0% (inverter rated
current)
0.1% 100.0% ×
F7.08
Current loop’s
proportional gain KP
0 ~ 9999
1
500
○
F7.09
Current loop’s integral
time KI
0 ~ 9999
1
300
○
F7.10
Filtering coefficient
0 ~ 63
1
27
○
7.9
Communication
Parameters
F8
(Reserved)
Parameter
Name
Setting range
Min.
unit
Default Mod.
F8.00
Modbus baud rate
selection
0: 1200bps
1: 2400bps
2: 4800bps
3: 9600bps
4: 19200bps
5: 38400bps
6: 76800bps
7: 125000bps
1 4 ×