80
“Extended time” procedure
Section 4: Orifice plate installation and removal instructions
Owner and operator manual
January 2015
3-9008-001 Rev M
15.
Once the Clamping Bar Screws (11) are loose, rotate the Upper Plate Carrier Shaft (7)
located in the Top (14) with the Operating Wrench (2), until the Plate Carrier (8DM or
8DMC) taps against the Sealing Bar (9 or 9HP) freeing it from the Top (14).
16.
Slide the Clamping Bar (12 or 12HP) containing the Clamping Bar Screws (11), the
Sealing Bar (9 or 9HP) from the Top (14).
Step 16-17
17.
Remove the Sealing Bar Gasket (9A, 9A-HP or 9CF) from the Top (14).
18.
Rotate the Upper Plate Carrier Shaft (7), located in the Top (14) with the Operating
Wrench (2), until the Plate Carrier (8DM or 8DMC) extends outside of the Top (14) and