40
Orifice Plate Installation
Section 2: Installation
Owner and operator manual
January 2015
3-9008-001 Rev M
The diagram below depicts the proper orientation of the Plate Carrier (8DM or 8DMC) assembly
prior to lowering it into the measurement position in the Senior.
Figure 2-4 Orientation of Plate Carrier (8DM or 8DMC) Prior to Installation
NOTES:
1.
The gear rack side of the Plate Carrier (8DM or 8DMC) assembly must face the downstream direction of flow.
2.
If the Orifice Plate (13) bore has a bevel, the bevel shall face the downstream direction of flow.
7.
Rotate the Upper Plate Carrier Shaft (7) a minimum of 1/4 turns OPPOSITE of the
direction used to lower the Plate Carrier (8DM or 8DMC) assembly. This will allow it to
“align” itself with the Top (14) shaft gear teeth.
8.
Once the Plate Carrier (8DM or 8DMC) assembly is aligned, rotate the Upper Plate
Carrier Shaft (7) in the direction to lower it from the Top (14) to the Body (4).
9.
Once the Plate Carrier (8DM or 8DMC) assembly is clear of the Upper Plate Carrier Shaft
(7), rotate the Lower Plate Carrier Shaft (6) until the Plate Carrier (8DM or 8DMC)
assembly is completely inserted into the Body (4).