“Extended time” procedure
Section 4: Orifice plate installation and removal instructions
Owner and operator manual
January 2015
3-9008-001 Rev M
Important
Resistance to turning will be present when the Orifice Plate Carrier (8DM or 8DMC) is
approaching its proper measurement position due to friction between the Senior Body (4) and
the Orifice Plate (13) seal.
44.
Once the Orifice Plate Carrier (8DM or 8DMC) is positioned in the Body (4), turn the
Slide Valve Shaft (5) using the Operating Wrench (2) into the CLOSED position.
Step 44
Step 45
45.
Close the Equalizer Valve (1).
PRESSURIZED FLUID HAZARD
When opening the bleeder valve (10B) or venting the Top (14) thru the bleeder valve (10B),
direct the released pressurized fluid and/or gas to safe area away from any individual in
accordance with local environment regulations.
The bleeder valve (10B) releases pressurized fluid that may cause contamination and/or
accumulation of volatile gas mixtures. Failure to do so may cause serious injury or death.