84
“Extended time” procedure
Section 4: Orifice plate installation and removal instructions
Owner and operator manual
January 2015
3-9008-001 Rev M
24.
Open the Bleeder Valve (10B) with the Operating Wrench (2)
Step 24
Steps 25 and 26 are ONLY required for the Seniors equipped with grease assisted, metal-to-
metal slide valves. Personnel operating Seniors equipped with O-Ring seal “soft seat” design
slide valves skip to step 27.
25.
Remove the stem from the Grease Gun (23) with the Operating Wrench (2) and insert a
Daniel lubricant stick into the Grease Gun (23).
Step 25
Step 25A