94
“Extended time” procedure
Section 4: Orifice plate installation and removal instructions
Owner and operator manual
January 2015
3-9008-001 Rev M
Step 47
Step 47A
PRESSURIZED FLUID HAZARD
Using the Grease Gun (23), inject the grease into the slide valve seat channels at a rate of 4 to 6
turns per minute and only under the following conditions:
• Bleeder Valve is open.
• Sealing Bar/Clamping bar is in place and tight.
Injection of the grease at a faster rate will lead to the separation of the valve strip from the valve
seat, resulting in release of pressurized fluid which may cause serious injury or death.