Unidrive M200-201 Quick Start Guide
7
Issue Number: 6
Table 2-2 AI Backup adaptor
3
Mechanical installation
The drives can be panel mounted with 0 mm space between the drives. For further information on
mechanical installation refer to the
Drive User Guide.
To remove the terminal cover, use a flat bladed screwdriver to rotate the terminal cover locating clip
by approximately 30° in a counter clockwise direction, and then slide the cover down.
Type
Option module
Name
Further Details
Communications
AI-485 Adaptor
See
Drive User Guide
Backup
AI-Backup Adaptor
AI-Smart Adaptor
Drive
Size
H
W
D
M1
M2
∅
A
B*
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
1
160
6.30
75
2.95 130 5.12 143
5.70
53
2.08
5
0.2
0
0.00
100
3.93
2
205
8.07
78
3.07 150 5.91 194
7.63
55
2.17
5
0.2
3
226
8.90
90
3.54 160 6.30 215
8.46
70.7 2.80
5
0.2
4
277 10.91 115 4.53 175 6.89 265
10.43
86
3.40
6
0.23
A minimum clearance of 100 mm above and below Frame 01 to 04 products is required
for applications where the product is subjected to rated load and rated ambient
temperature.
* A minimum clearance of 50 mm above and below Frame 01 to 04 products is permissible
in applications where either the ambient operating temperature is 35 °C or less or the
average output current is derated by 20 %.
A
W
M2
M2
B
D
B
A
H M1
11 mm
(0.43 in)
Cover
release
NOTE
NOTE
Unidrive M200 201 Quick Start Guide English Iss6.book Page 7 Thursday, September 10, 2015 1:48 PM