40
Unidrive M200-201 Quick Start Guide
Issue Number: 6
This parameter selects the function of Digital Input 5.
Defines the behaviour of digital output 1.
00.034 {08.005}
Digital Input 5 Mode
RW
Txt
US
OL
Ú
Input (0), th.Sct (1), th (2), th.Notr
(3), Fr (4)
Ö
Input (0)
RFC-A
Value
Text
Function
0
Input (0)
Digital input
1
th.Sct (1)
Temperature measurement input with short circuit detection
(Resistance <50
Ω
)
2
th (2)
Temperature measurement input without short circuit detection but
with th trip
3
th.Notr (3)
Temperature measurement input with no trips
4
Fr (4)
Frequency input
00.035 {08.091}
DO1 Control (terminal 10)
RW
Num
US
OL
Ú
0-21
Ö
0
RFC-A
Value
Description
0
User defined by Digital IO1 Source/Destination A, Digital IO2 Source/Destination A,
Relay 1 Output Source A,
or Relay 2 Output Source A.
1
Drive running signal (RUN)
2
Frequency arrived signal (FAR)
3
Frequency level detection signal (FDT1)
4
Frequency level detection signal (FDT2)
5
Overload detection signal (OL)
6
Power off state (LU)
7
External fault stop (EXT)
8
Frequency upper limit (FHL)
9
Frequency lower limit (FLL)
10
Drive running at zero frequency
14
Drive (RDY)
15
Drive OK
18
Brake release
19
Torque limiting (Valid while the torque is limited by torque limiting value 1/2)
20
Forward or reverse
21
Motor 1 or 2