Caution:
l
The sensor head is fragile and can easily be damaged. Using cable ties to secure the sensor head or sensor cable is not recommended and
invalidates the warranty.
To help place the appliance sensor, the parameter calibration 1 (
C A1
) defines an offset temperature.
l
See "calibration 1 (CA1)" on page 69
3.2
how to mount the condenser sensor
This sensor measures the temperature of the refrigeration system. Excessive condenser temperature is usually due to poor
preventive maintenance, i.e poorly cleaned condenser, or condenser fan failure.
3.2.1
condenser sensor
ems controllers can generate alarms if the refrigeration system temperature rises too high.
The value of the high temperature is set by measuring the refrigeration system temperature, when the condenser is approx-
imately 75% blocked. The temperature is then set as the value of the condenser high temperature (
Ht
) parameter.
l
See "condenser high temperature (Ht)" on page 76
For example, fix using a metal pipe clip or direct fitting, as shown below.
Elstat can supply pipe clips for 6-8mm and 8-10mm pipes.
Caution:
l
Do not use cable ties.
The head of the sensor is fragile and can be easily damaged. Using cable ties to secure the sensor head or sensor cable invalidates the war-
ems55advanced and ems55Radvanced / General Use
14 of 84