alignment
dimensions
notes
5mm (0.2in)
+/- 2mm (0.07in)
The diagram below shows the horizontal, vertical, and gap alignment between the door switch and the activator for open and
closed doors.
For best results, elstat recommends that enhanced door switches are used with enhanced door switch activators. Per-
formance will not be guaranteed if:
l
enhanced activators are paired with current door switches
l
enhanced door switches are paired with current activators.
Enhanced door switches and enhanced activators must be used as a set.
4.3
how to mount door switches on double-door coolers
For double-door coolers, two door switches must be connected in series.
Connect two door switches in series as follows:
1. Remove the two wires from one of the connectors. Be careful not to damage the terminals.
2. Remove the white wire from the second connector. Again, be careful not to damage the terminal.
3. Insert the white wire of the first cable into the connector of the second cable ensuring that the terminal is in the correct orientation.
4. Connect the red wire from the first cable and the white wire from the second cable together using a butt splice or similar.
The image below shows two door switches connected in series.
ems55advanced and ems55Radvanced / General Use