9
elstat parameter loader
The elstat parameter loader loads the parameter settings defined in XML files to the parameter programming tool (dongle).
The parameter programming tool (dongle) connects to the parameter loader using a USB docking cradle and COM port on a
host computer.
The following specification of computer is required for operation:
l
Windows XP, Windows Vista, or Windows 7
l
2 MB of disk space.
9.1
what are the XML files?
The XML files are supplied from elstat and include parameter information about each XML file.
The XML files contain the parameter settings to be downloaded to the ems controller, and the checksum values. Parameters
and their values determine how the ems controller operates the cooler.
XML files cannot be manually edited.
If an operator or engineer tries to edit an XML file, the parameter loader displays a message stating the XML file is
not valid
.
The table below details the naming conventions of the XML file names for ems controllers.
ems controller
XML file name
ems25
EMS25BAS-CCCC-NNNNN-XXXXX
ems25
+
EMS25PLUS-CCCC-NNNNN-XXXXX
ems25
advanced
EMS25ADV-CCCC-NNNNN-XXXXX
ems55
advanced
EMS55ADV-CCCC-NNNNN-XXXXX
ems75vr and ems75vri EMS75VR-CCCC-NNNNN-XXXXX
ems75sz
EMS75SZ-CCCC-NNNNN-XXXXX
Where:
l
CCCC is the cooler type.
The cooler types are
GDC
(glass door cooler),
OFC
(open front cooler), and
VEND
(vending machine).
l
NNNNN is a unique five-digit identification number.
l
XXXXX is information supplied on the completed the parameter request form.
For example, the cooler type, manufacturer, region, and so on.
This is specific to individual coolers.
ems55advanced and ems55Radvanced / General Use
53 of 84