saving
temperature
disable
on if the saving mode temperature is disabled.
The controller maintains
ready mode
temperature at all times.
red
motion
on when motion is detected.
red
Push buttons:
button
name
function
defrost
starts a defrost cycle.
set
selects menu options and scrolls through the parameters.
up
increases the parameter values.
down
scrolls down menus, decreases parameter values, and can-
cels alarms.
2.4
environmental ratings
The table below details the general characteristics of ems55 series controllers.
characteristic
value
IP rating
IPX5
maximum operating temperature
55
o
C (131
o
)
minimum operating temperature
0
o
C (32
o
F)
housing material
black polycarbonate
2.5
ems55 series relay ratings
The table below details the relay ratings of ems55
advanced
and ems55R
advanced
controllers.
relay
maximum IEC rating
@100-240VAC
maximum UL ratings
@ 120VAC
compressor 10(10)A, p.f. 0.6
16 FLA, 96 LRA
lights
4(4)A, p.f. 0.6
120VAC, 60Hz, 250W ballast
evaporator
fan
4(4)A, p.f. 0.6
4.4 FLA, 13.1 LRA
2.6
ems55
advanced
and ems55R
advanced
wiring diagram
The wiring diagrams for the ems55
advanced
and ems55R
advanced
are shown below.
ems55advanced and ems55Radvanced / General Use