E7 Over Temperature error sequence
deactivated.
Over temperature error was ended
I0007
Capacitor group test has been performed.
Group #(1) Found faulty by: Err (2)
System test was ended with some faulty capacitors,
indicating the faulty groups (1) and errors found (2)
I0008
Capacitor group test has been performed.
No group errors found.
System test was ended and all the groups are ok
I0009
C
CT polarity was changed automatically
during installation procedure.
The system automatically changed the system internal
CT polarity during site installation
I0010
E6 synchronization error. Measurement
system was disabled.
The system could not synchronize
I0011
E6 synchronization error has been Cleared.
The system reengaged synchronization
I0012
Time settings were changed.
The operator changes the system time
I0013
Date settings were changed.
The operator changes the system date
I0014
System failed to recover from parameter
CRC error. Factory default parameter set
was activated.
Both copies of the parameters were corrupted and the
system automatically loaded default values
I0015
Automatic operation mode has been set.
User selected automatic mode of operation
I0016
Manual operation mode has been set.
User selected manual mode of operation
I0017
System was shut down. Alarm signal was set
ON.
The system was powered off
I0018
Parallel resonance has been detected at
H(1). Capacitors are disabled for the next (2)
sec while (3) steps were connected.
The system detected resonance in the network. The
lower harmony is displayed (1) and the groups that
were connected (3). The system is disabled for (2)
seconds.
Table 10: List of Events Log and Their Meaning
ID
Description
Cause
I0019
Alarm signal was set ON.
Alarm signal was activated
I0020
ALARM signal was cleared.
Alarm signal was de-activated
I0021
Power Factor Control has been activated.
The user selected Power Factor mode of operation
I0022
Reactive Energy Control (kVAr) has been
activated.
The user selected kVAr mode of operation
I0023
Target Power Factor set point was changed
The user set the target power factor to (1)
Содержание EQUALIZER-ST
Страница 1: ...1 www elspec ltd com December 2014 SMX 0609 0101 User Manual EQ ST V16 16 ...
Страница 99: ...99 www elspec ltd com December 2014 SMX 0609 0101 User Manual EQ ST V15 3 PHASE DELTA CONFIGURATION ...
Страница 100: ...100 www elspec ltd com December 2014 SMX 0609 0101 User Manual EQ ST V15 ...
Страница 101: ...101 www elspec ltd com December 2014 SMX 0609 0101 User Manual EQ ST V15 SINGLE PHASE CONFIGURATION ...