BeeProg2 / BeeProg2C /
Comment to above picture:
picture C) Connection of pins 15 and 16 when are configured as logical signal needed for ISP
programming
pictures D) E) When pins 15 and 16 are configured as status of LED OK and LED ERROR
picture D) before first action with desired ISP device
picture E) after first action with desired ISP device
Notes:
When LED OK or LED ERROR ON (shine), this status is presented as logical H, level
of H is 1,8V - 5V depend on H level of desired ISP device.
When LED OK or LED ERROR OFF (not shine), this status is presented as logical L, level of
L is 0V - 0,4V.
The above mentioned values are provided to understand (and also to exactly calculate) the
value of resistors, which isolate (separate) the programmed chip and target system.
Specification of ISP connector pins depends on the device, which you want to program. You
can find it in the control SW for programmer (PG4UW), menu
Device / Device Info (Ctrl+F1)
.
Be aware, the ISP programming way of respective device must be selected. It is indicated by
(ISP) suffix after name of selected device.
These specifications correspond with application notes published of device manufacturers.
Used application notes you may find on
section Support / Application
Notes.
Note:
Pin no. 1 is signed by triangle scratch on ISP cable connectors
.
As ISP connectors are used 20 pins connectors 09185207813 from Harting or other
compatible connector.
BeeProg2 / BeeProg2C / ISP cable
Warnings:
•
When
you use BeeProg2 /
BeeProg2C / as
ISP programmer
,
don’t insert
device to
ZIF socket
.
•
When
you program devices in
ZIF socket
,
don’t insert
ISP cable to
ISP connector
.
•
Use only
attached ISP cable
. When you use other ISP cable (other material, length…),
programming may occur unreliable.
•
BeeProg2 / BeeProg2C /
can
supply
programmed device (pin 1 of ISP
connector) and target system (pins 19 and 20 of ISP connector) with limitation (see
Technical specification / ISP connector).
•
BeeProg2 / BeeProg2C / apply programming voltage to target device and
checks his value (target system can modify programming voltage). If the programming
voltage is different as expected, no action with target device will be executed.
37
Содержание SEEprog
Страница 7: ...Introduction Introduction 7...
Страница 12: ...ELNEC s r o Quick Start 12...
Страница 15: ...Detailed description Detailed description 15...
Страница 16: ...ELNEC s r o BeeHive204 16...
Страница 30: ...ELNEC s r o BeeProg2 BeeProg2C BeeProg 30...
Страница 45: ...SmartProg2 SmartProg2 45...
Страница 54: ...ELNEC s r o MEMprog2 54...
Страница 61: ...SEEprog SEEprog 61...
Страница 66: ...ELNEC s r o Setup 66...
Страница 75: ...Setup Step 6 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway 75...
Страница 77: ...PG4UW PG4UW 77...
Страница 144: ...ELNEC s r o PG4UWMC 144...
Страница 154: ...ELNEC s r o Common notes 154...
Страница 168: ...ELNEC s r o Troubleshooting and warranty 168...