ELNEC s. r. o.
When PG4UW receives the commands, it will do following procedures:
1. loads data file c:\15001-25001\file_10.bin
2. saves the currently selected device settings and buffer data to project file
c:\projects\project_10.eprj
If the result of operations performed is OK, PG4UWcmd application will return ExitCode (or
ErrorLevel) value 0.
If there are some errors (can not load file or save to project file), PG4UWcmd application will
return ExitCode value equal or greater than 1.
Note:
When using the above commands, user must be sure the PG4UW is not performing
any device operation, for example device programming. If the PG4UW is busy, it will refuse
the commands and returns error status (ExitCode equal or greater than value 1).
Hardware
Due a large variety of parallel port types, a case may occur when the programmer cannot "get
concerted" with the PC. This problem may be shown as none communication between the PC
and the programmer, or by unreliable communication. If this behavior occurs, try to connect
your programmer to some other PCs or other parallel ports near you.
If you find none solution, please document the situation, i.e., provide us an accurate
description of your PC configuration, including some other circumstances bearing on the
problem in question, and advise the manufacturer of your problem. Don’t forget please enter
of PC type, manufacturer, speed, operation system, resident programs; your parallel port I/O
manufacturer and type. Use please
Device problem report
form for this purpose.
Warning:
Class A ITE notice
Devices described at this manual are class A products. In domestic environment this products
may cause radio interference in which case the user may be required to take adequate
measures.
Because BeeHive204, BeeProg2, BeeProg2C and have internal power supply,
follow these special precautions:
•
Circuit breakers (overcurrent protection) must be a part of building electrical installation.
•
Pull out power cord plug from outlet to disconnect programmer from mains. The outlet
must be placed near to programmer and must be easy accessible.
ISP (In-System Programming)
Definition
In-system programming
allows programming and reprogramming of device positioned
inside the end system. Using a simple interface, the ISP programmer communicates serially
with the device, reprogramming nonvolatile memories on the chip. In-system programming
eliminates the physical removal of chips from the system. This will save time and money, both
during development in the lab, and when updating the software or parameters in the field.
Target device
is the device (microcontroller, PLD, etc…), which is to be in-system
programmed.
162
Содержание SEEprog
Страница 7: ...Introduction Introduction 7...
Страница 12: ...ELNEC s r o Quick Start 12...
Страница 15: ...Detailed description Detailed description 15...
Страница 16: ...ELNEC s r o BeeHive204 16...
Страница 30: ...ELNEC s r o BeeProg2 BeeProg2C BeeProg 30...
Страница 45: ...SmartProg2 SmartProg2 45...
Страница 54: ...ELNEC s r o MEMprog2 54...
Страница 61: ...SEEprog SEEprog 61...
Страница 66: ...ELNEC s r o Setup 66...
Страница 75: ...Setup Step 6 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway 75...
Страница 77: ...PG4UW PG4UW 77...
Страница 144: ...ELNEC s r o PG4UWMC 144...
Страница 154: ...ELNEC s r o Common notes 154...
Страница 168: ...ELNEC s r o Troubleshooting and warranty 168...