![Elnec SEEprog Скачать руководство пользователя страница 103](http://html1.mh-extra.com/html/elnec/seeprog/seeprog_user-manual_2395127103.webp)
PG4UW
S / N size option defines the number of bytes of serial value which will be written to buffer.
For Bin (binary) serialization modes values 1-8 are valid for S / N size and for ASCII
serialization modes values 1-16 are valid for S / N size.
Address
Address option specifies the buffer address, where serial value has to be written. Note that
address range must be inside the device start and device end addresses. Address must be
correctly specified so the last (highest or lowest) byte of serial value must be inside device
start and device end address range.
Start value
Start value option specifies the initial value, from which serialization will start. Generally, the
max. value for serialization is $1FFFFFFF in 32 bit long word.
When the actual serial value exceeds maximum value, three most significant bits of serial
number are set to zero. After this action the number is always inside 0..$1FFFFFFF interval
(this is basic style of overflow handling).
Step
Step options specify the increment step of serial value incrementation.
S / N mode
S / N mode option defines the form in which serial value has to be written to buffer. Two
options are available:
•
ASCII
•
Bin
ASCII
- means the serial number is written to buffer as ASCII string. For example number
$0528CD is in ASCII mode written to buffer as 30h 35h 32h 38h 43h 44h (‘0’ ‘5’ ‘2’ ‘8’ ‘C’ ‘D’),
i.e. six bytes.
Bin
- means the serial number is written directly to buffer. If the serial number has more than
one byte length, it can be written in one of two possible byte orders. The byte order can be
changed in „Save to buffer“ item.
Style
Style option defines serial number base. There are two options:
•
Decimal
•
Hexadecimal.
Decimal
numbers are entered and displayed using the characters '0' through '9'.
Hexadecimal
numbers also use characters 'A' through 'F'.
The special case is Binary Dec, which means BCD number style. BCD means the decimal
number is stored in hexadecimal number, i.e. each nibble must have value from 0 to 9.
Values A to F are not allowed as nibbles of BCD numbers.
Select the base in „Style“ options before entering numbers of serial start value and step.
Save to buffer
Save to buffer option specifies the serial value byte order to write to buffer. This option is
used for Bin S / N mode (for ASCII mode it has no effect).
Two options are available:
•
LSByte first
(used by Intel processors) will place the Least Significant Byte of serial
number to the lowest address in buffer.
•
MSByte first
(used by Motorola processors) will place the Most Significant Byte first to the
lowest address in buffer.
103
Содержание SEEprog
Страница 7: ...Introduction Introduction 7...
Страница 12: ...ELNEC s r o Quick Start 12...
Страница 15: ...Detailed description Detailed description 15...
Страница 16: ...ELNEC s r o BeeHive204 16...
Страница 30: ...ELNEC s r o BeeProg2 BeeProg2C BeeProg 30...
Страница 45: ...SmartProg2 SmartProg2 45...
Страница 54: ...ELNEC s r o MEMprog2 54...
Страница 61: ...SEEprog SEEprog 61...
Страница 66: ...ELNEC s r o Setup 66...
Страница 75: ...Setup Step 6 Click on Continue Anyway button For Windows Vista Click Install this driver software anyway 75...
Страница 77: ...PG4UW PG4UW 77...
Страница 144: ...ELNEC s r o PG4UWMC 144...
Страница 154: ...ELNEC s r o Common notes 154...
Страница 168: ...ELNEC s r o Troubleshooting and warranty 168...