PG4UW software
115
<ordnum> is decimal order of the file. If there are any report files with the same name, then
order for new report file is incremented about order of existing files.
<prjname> is project file name of recently used project, and without the project file name
extension.
Example 1:
Let's use the project file c:\myproject.eprj and directory for Job Report set to d:\job_reports\.
There are no report files present in the Job Report directory.
The final Job Report file name will be:
d:\job_reports\job_report_000_myproject.jrp
Example 2:
Let's use the conditions from Example 1, but assume there is already one report file present.
Name of this file is d:\job_reports\job_report_000_myproject.jrp
The final Job Report file name of new report will be:
d:\job_reports\job_report_001_myproject.jrp
Note, the order inside file name is incremented by 1.
When
Automatically save Job Report file
setting is set, no Job Report dialogs appears
when generating Job Report. Newly generated Job Report is saved to file without any dialogs
or messages (if no error occurs while saving to file).
If the checkbox
Automatically save Job Report file
is unchecked, the PG4UW will show
Job Report dialog every time needed.
In the Job Report dialog user can select operation to do with Job Report. If user selects no
operation (Close button), the Job Report will be written to PG4UW Log Window only.
Automatic YES!
Allows user to override default settings (as preset in PG4UW software) of indication for the
state when the programmer and the software wait for withdrawing programmed device and a
new one will be inserted in active Automatic YES! mode.
Default (as preset in software)
- the programmer indicates the state when a device is
programmed and the programmer with software wait for inserting a new device as preset in
the software for respective programmer. Multi-sockets programmers (the programmers with
more than one ZIF socket) do not indicate this state, see description for
Not indicated (quiet
mode)
. Single-socket programmers (the programmers with one ZIF socket) indicate this state
by LED Busy blinking, see description for
By LED Busy blinking
setting.
Not indicated (quiet mode)
– the programmer, regardless of the number of ZIF sockets,
does not indicate the state when a device is programmed and the programmer with software
wait for inserting a new device. After an operation with a device only one of the status LEDs
Error or OK lights, in dependence on the result of previous operation. This LED goes off
immediately after detecting removal of a device from the ZIF socket.
By LED Busy blinking
- the programmer, regardless of the number of ZIF, indicates the
state when a device is programmed and the programmer with software wait for inserting a
new device mode by blinking with the LED Busy. After an operation with a device is done,
Содержание BeeHive304
Страница 6: ...Elnec s r o 6 Introduction ...
Страница 10: ...Elnec s r o 10 Quick Start ...
Страница 13: ...Detailed description 13 Detailed description ...
Страница 14: ...Elnec s r o 14 BeeHive304 ...
Страница 29: ...BeeProg3 29 BeeProg3 ...
Страница 43: ...Setup 43 Setup ...
Страница 48: ...Elnec s r o 48 Step 9 Installation process will start Step 10 Click Finish button to finish setup ...
Страница 58: ...Elnec s r o 58 PG4UW software ...
Страница 125: ...PG4UWMC software 125 PG4UWMC software ...
Страница 138: ...Elnec s r o 138 Installation procedure customized ...
Страница 143: ...Common notes 143 Common notes ...
Страница 148: ...Elnec s r o 148 Troubleshooting and warranty ...
Страница 152: ...Elnec s r o Jana Bottu 5 SK 080 01 Presov Slovakia www elnec com ZLI 0330 ...