61
Setscrew
1. Remove the spool stand, right cover, left cover and
tension control panel (see pages 4 – 6).
2. Open the factory adjusting menu window and press
the
Needle key to open the Needle Change adjusting
window.
3. Turn the lateral movement idler gear to set the lateral
movement cam at the middle of the flat portion.
The indication next to
NCHM Init Sen should be “H”.
To adjust the stop position, loosen the setscrew and
turn the stop positioning shield plate.
Tighten the setscrew.
NOTE:
The shield plate should not interfere with the sensor.
4. Press Init key to move the head to the stop position
and check if “
L” is indicated.
5. Attach the parts removed in step 1.
Lateral
movement
idler gear
Stop position
shield plate
Phase reference of the
lateral movement cam and
stop position shield plate
Adjusting the Moving Head Stop Position
Содержание eXpressive 970