22
Step 1: Open the Needle Change Adjusting
Window of the Factory Adjusting Mode.
Select needle bar No. 1.
Step 2: Removing the Needle Bar
1 Remove the tension unit cover, lower thread guide
plate and thread catcher panel (head cover).
2 Remove the 2 setscrews (A) and the tension control
unit.
3 Loosen the needle clamp screw and remove the
needle.
4 Lower the needle bar. Loosen the hexagonal socket
screw and remove the needle clamp.
5 Remove the setscrew (B), presser foot and cushion.
Replacing the Presser Foot Return Spring and Washer
Setscrew (A)
Setscrew (A)
Needle clamp
screw
Hexagonal
socket screw
Setscrew (B)
Presser foot
Cushion