Installation/Configuration ER600
25
8.2
KP600 KEYPAD
Figure 9 - KP600 led keypad
Ref.
Description
Use or indications provided
1
Keypad state LED (blue/amber)
Blue LED on for 5 seconds: the system is in normal operating mode.
The blue LED blinks for 5 seconds: it indicates flat battery in normal operating
mode.
Amber LED on: the system is in test mode.
Amber LED blinking: in Test mode, this indicates flat battery.
2
System state LED (blue/red)
Red LED on: the system is in Total Armed state.
Red LED blinking: the system is in Partial Armed state.
Blue LED on: the system is in disarmed state.
Blue LED blinking: error for the following reasons:
No reply sent to control unit within 4 seconds.
User error code.
Request to pass to Partial Armed state when the Total Armed state.
Forced arming request.
3
Future use
Not used
4
Total arming key
Enter a four-digit user code and press the
key. If there are no faults and arming
was successful, the red system state LED will light up and the keypad will beep.
5
Partial arming key
Enter a four-digit user code and press the
key. If there are no faults and
arming was successful, the red system state LED will light up and the keypad will
beep.
6
System state request key
Indicated on system state LED (see indications provided by Ref. 2)
7
Disarming key
Enter a four-digit user code and press the
key, to disarm all associated
partitions.
8-9
Not used
10
Acquisition key
11-12
Not used
13
Function keys
Pressing the two keys at the same time will start the function associated to them
14
Battery isolator
15
Assembly holes
16
Tamper