22
Installation/Configuration ER600
6.9
RESETTING FACTORY SETTINGS
6.9.1
Partial reset
Reset the control panel programming to default.
The following are not deleted: the Diagnose Log., the codes, the keys, and the device acquisitions.
To carry out the partial reset:
1. Select the item
«MAINTENANCE» / «PARTIAL RESET»
in the Installer menu and confirm with
OK
.
2. When asked
«ARE YOU SURE?»
press
OK
to confirm or
ESC
to cancel the operation.
3. The message
«PARTIAL RESET» «IN PROGRESS...»
will appear when
OK
is pressed and the buzzer will sound.
«MAINTENANCE» «PARTIAL RESET»
will appear then the operation is concluded.
4. At this point, the reprogramming of the system can be started.
6.9.2
Global reset
Resets the control panel programming and all the devices connected to the system data BUS to default.
In reference to the ER600 radio expansion it is also necessary to reacquire all the radio devices associated with it (IR, DC, RC, KP,
sirens).
IMPORTANT!
Following the Global reset command, it is necessary to carry out the local reset of all the radio sirens of the
system and then reacquire them.
To carry out the Global reset:
1. Select the item
«MAINTENANCE» / «GLOBAL RESET»
in the Installer menu and confirm with
OK
.
2. When asked
«ARE YOU SURE?»
press
OK
to confirm or
ESC
to cancel the operation.
3. The message
«IN PROGRESS...»
will appear when
OK
is pressed and the buzzer will sound.
4. At the end of the operation, a series of full stops will appear on the display. Turn off the system and restart from Chapter
6.9.3
Resetting hardware to factory settings
Only in particular cases, like when there is no keypad to access the menu, if it is in any case necessary to reset the control panel to
default, can the Reset hardware be used. Remember that this method has the same effect as the Global reset in that only the control
panel is reset to default. When this procedure is used, the individual devices maintain their programming.
When this operation is completed, it is therefore essential to reset each device individually and reacquiring devices.
In reference to the ER600 radio expansion, it is also necessary to reacquire all the radio devices associated with it (IR, DC, RC, KP,
sirens).
IMPORTANT!
Following the Reset hardware command, it is necessary to carry out the local reset of all the radio sirens of the
system and then reacquire them.
To carry out the Reset hardware, follow the instructions below:
1. Turn off the control panel completely.
2. Set the Dip switch to 1 to ON.
3. Reconnect the control panel to the power supply; during the initialisation phase all the parameters will be reset to default.
4. When the green RUN LED of the control panel begins to flash, reposition the Dip-switch 1 to OFF.
5. Reprogram the control panel parameters.
6.9.4
Resetting devices
The deletion of any device in the system and connected to the bus must be done according to the procedure described in paragraph
Only in special
cases, for example if a device has already been acquired by another control panel or following a “Resetting hardware to
default" can the Reset devices been used.
IMPORTANT!
Remember that this method only deletes the data on the device. Of the device is also acquired on the control
panel, it will continue to be present there, generating and signalling a tamper error.
To cancel the address of any device and reset its programming to default, follow the instructions below:
1. Disconnect power from the device and reconnect it. The yellow LED will begin flashing slowly.
2.
Within 10 seconds, press and hold down the “PROG” button for about 5 seconds until the yellow LED flashes at a different speed.
3. Release the button. The Reset phase is concluded. The yellow LED will continue to flash until the device is reacquired.
In reference to the ER600 radio expansion reset, it is also necessary to reacquire all the radio devices associated with it (IR, DC, RC,
KP, sirens).
IMPORTANT!
Following the Reset command of the ER600 radio expansion, it is necessary to carry out the local reset of all the
radio sirens of the system.