210-10 ADL
17/62
599 75 60-77
Electrical Work:
CAPACITY
POWER SUPPLY
INPUT RATED AMP
Switch/Fuse
CABLE SIZE
EXH09HL1W
EXH12HL1W
220-240V~/50Hz
16A/16A
1.5 mm
2
(power cord)
1.5 mm
2
(connecting cable)
Connect the Cable to the Indoor Unit
(
instruction manual
)
1.The inside and outside connecting cable can be
connected without removing the front panel.
2. Connecting cable between indoor unit and outdoor unit
shall be approved polychloroprene sheathed flexible
cord,type designation H07RN-F or heavier cord.
3.Life the indoor unit panel up,remove the electrical
box cover by loosening the screw.
4.Ensure the colour of wires of outdoor unit and the
terminal Nos. are the same to the indoor respectively.
5.Wrap those cables not connected with terminals with
insulation tapes,so that they will not touch any electrical
components.Secure the cable onto the control board
with the cord clamp.
Connect the Cable to the Outdoor Unit
1.Remove the electrical control board cover from the
outdoor unit by loosening the screw.
2.Connect the connective cables to the terminals as
Identified with their respective matched numbers on
the terminal block of indoor and outdoor unit.The connective
cable to power supply shall be approved polychloroprene sheathed flexible
cord,type designation H07RN-F or heavier cord.
3.Securd the cable onto the control board with the cord
clamp.
4.To prevent the ingress of water,form a loop of the connective
cable as illustrated in the installation diagram of indoor and outdoor
units.
5.Insulate unused cord(conductors) with PVC-tape.Process them so
they could not touch any electrical or metal parts.
Содержание EXH09HL1W
Страница 2: ...2010 10 ADL 2 62 599 73 60 74 ...
Страница 5: ...210 10 ADL 5 62 599 75 60 77 2 ESD Requirements ...
Страница 6: ...210 10 ADL 6 62 599 75 60 77 ...
Страница 13: ...210 10 ADL 13 62 599 75 60 77 EXH09HL1W outdoor EXH12HL1W outdoor ...
Страница 28: ...210 10 ADL 28 62 599 75 60 77 BOTTOM VIEW ...
Страница 37: ...210 10 ADL 37 62 599 75 60 77 H6 Malfunction Flowchart ...