210-10 ADL
18/62
599 75 60-77
7. Electronic Function
1.Temperature Parameters
◆
Indoor preset temperature (Tpreset)
◆
Indoor ambient temperature (Tamb.)
2.Basic Functions
(The temperature in this manual is expressed by Centigrade. If Fahrenheit is used, the switchover between
them is Tf=TcX1.8+32.)
Once the unit is energized, the compressor shall never be restarted except 3mins interval at least. For the first energization, if
the unit is at off status before power failure, the compressor can be restarted without 3-min delay. But if the unit is at ON status
before power failure, the compressor shall be restarted with 3mins delay. Once the compressor is started up, the compressor
won't stop running within 6mins with the change of room temperature.
(1)Cooling Mode
①
Cooling Conditions and Process
When Tamb.
≥
Tpreset, the unit starts cooling operation. In this case, the compressor and the outdoor fan operate and the
indoor fan operates at set speed.
When Tamb. ≤Tpreset-3
℃
, the compressor and the outdoor fan stop while the indoor fan runs at set speed.
When Tpreset-3
℃
<
Tamb.
<
Tpreset, the unit will maintain its previous running status.
In cooling mode, the temperature setting range is 16
~
30
℃
; Indoor unit displays operation icon, cooling icon and set
temperature.
(2) Dry Mode
①
Drying Conditions and Process
When Tamb.>Tpreset, the unit operates in cooling mode. Meanwhile, compressor and outdoor fan operate, and indoor fan
operates at set fan speed (low fan speed, quiet fan speed).
When Tpreset-3
℃<
Tamb.
≤
Tpreset, the unit keeps previous operation status.
When Tamb.
≤
Tpreset-3
℃
, compressor, outdoor fan and indoor fan operate at set fan speed (low fan speed, quiet fan speed).
Under this mode, the temperature setting range is 16
~
30
℃
. Display displays operation icon, drying icon and set temperature.
Содержание EXH09HL1W
Страница 2: ...2010 10 ADL 2 62 599 73 60 74 ...
Страница 5: ...210 10 ADL 5 62 599 75 60 77 2 ESD Requirements ...
Страница 6: ...210 10 ADL 6 62 599 75 60 77 ...
Страница 13: ...210 10 ADL 13 62 599 75 60 77 EXH09HL1W outdoor EXH12HL1W outdoor ...
Страница 28: ...210 10 ADL 28 62 599 75 60 77 BOTTOM VIEW ...
Страница 37: ...210 10 ADL 37 62 599 75 60 77 H6 Malfunction Flowchart ...