210-10 ADL
50/62
599 75 60-77
(19) Power Protection
L9 is displayed on indoor unit
Yellow LED lamp of outdoor unit blinks for 9 times
When Pc≥1900w, if Pc≤1800w for continuous 3min, the unit will resume normal operation;
When Pc
B
≥2000w, the unit will operate at decreased frequency;
Wh
en Pc≥2100w, compressor stops operation.
# Check if power of compressor meets the conditions mentioned above. Decrease the frequency so as to reduce the power to
less than 1800w for 3min. Then check if the compressor resumes operation.
(20) Other Normal Malfunction
COOL operation is normal but HEAT operation is unavailable.
HEAT operation is normal but COOL operation is unavailable.
It is usually due to K3 contact adhesion of outdoor controller, which can be judged by universal meter.
COOL
operation
is
normal
but
HEAT
operation is unavailable.
In HEAT mode, measure voltage
between two wire of 4-way-valve by AC
voltage grade of universal meter.
Voltage between 4V and
AC-L2(detection point 10)
is not around AC220V
If it is AC220V
Replace outdoor controller
Cut-off power supply and unplug two wire of
4-way-walve. Then measure if resistance
between the two wire is 1-2K
Resistance is too
large
Replace 4-way valve
4-way valve is
normal
The system of the unit is
abnormal
Содержание EXH09HL1W
Страница 2: ...2010 10 ADL 2 62 599 73 60 74 ...
Страница 5: ...210 10 ADL 5 62 599 75 60 77 2 ESD Requirements ...
Страница 6: ...210 10 ADL 6 62 599 75 60 77 ...
Страница 13: ...210 10 ADL 13 62 599 75 60 77 EXH09HL1W outdoor EXH12HL1W outdoor ...
Страница 28: ...210 10 ADL 28 62 599 75 60 77 BOTTOM VIEW ...
Страница 37: ...210 10 ADL 37 62 599 75 60 77 H6 Malfunction Flowchart ...