(9) Control of Left&Right Swing
After energization, swing will be restored to the starting point firstly and then stop at the middle position. When setting left&right
swing, swing blade has 7 statuses: left position
①
, secondary left position
②
, middle position
③
, secondary right position
④
, right
position
⑤
, swing between
①
and
⑤
, stop position. If left&right swing is set when turning on the unit, swing motor will drive blade
to swing between left and right.
When cancel left&right s
wing or swing hasn’t been set when turning on
the unit for the first time, blade will stop at current position. Left&right swing
will keep at original position when turning off the unit.
Swing is valid only when swing command is set and indoor fan operates.
(10) Display
①
Operation and Mode Icons
Upon energization within 3s, the unit will display all icons. Under standby state, running indicating mark is displayed. If the unit is
started by remote controller, running indicating mark gives off light; meanwhile, the mark of current running mode will be
displayed. If the light button is turned off, no mark will be displayed.
②
Display of Nixie Tube on Indoor Unit
When energized & started for the first time, the indoor unit defaults to displaying current set temperature (16
~
30
℃
). When set
temperature display is set by remote controller, it will display set temperature; when room temperature display is set, it will
display room temperature. After that, when operating the remote controller for other settings, the temperature display method
will keep original.
When operating the remote controller during room temperature display, the set temperature will be displayed for 5 seconds
firstly and then room temperature display returns.
“F1” will be displayed upon malfunction of room temperature sensor, “F2” upon malfunction of indoor unit tube temperature
sensor and “C5” upon malfunction of jumper cap.
(11) Memory Function
Memorized items: mode, up & down swing, light, set temperature and set fan speed.
When power is recovered after power failure, the unit will automatically start operation according to memorized status. After
power recovery, the unit without timer setting before power failure will operate according to the last setting; the unit with general
timer setting which has not been fulfilled before power failure will memorize the timer setting and re-calculate the time after
power recovery. If there is timer function in the last remote controller command but setting time has reached, the system will act
as timer on/off setting before power failure. After power failure, the system memorizes the operation states before power failure
without timer action. Clock timer can not be memorized.
(12) I FEEL Function
When I FEEL command is received and controller has received the ambient temperature sent by remote controller, the
controller will operate at the temperature sent by remote controller (For cold air prevention, the unit operates according to the
ambient temperature sensed by the air conditioner). If it only received I FEEL
command and hasn’t received the valid ambient
temperature, air conditioner will operate according to the ambient temperature sensed by itself. Remote controller will send
the ambient temperature to controller every 10min. If controller hasn’t received the ambient temperature sent by remote
controller for 11min, air conditioner will operate according to the ambient temperature sensed y itself. If I FEEl hasn’t been set,
ambient temperature will adopt the temperature sensed by air conditioner. Controller displays I FEEL ambient temperature
1
℃
~59
℃
。
(
13
)
Health, Cold Plasma Function
At ON status, press health button (if there isn’t health button on remote controller, health function is ON in default) on remote
controller can set health or cold plasma function. Health or cold plasma function can operate when it set ON and indoor fan
operates.
Содержание EXH09HL1W
Страница 2: ...2010 10 ADL 2 62 599 73 60 74 ...
Страница 5: ...210 10 ADL 5 62 599 75 60 77 2 ESD Requirements ...
Страница 6: ...210 10 ADL 6 62 599 75 60 77 ...
Страница 13: ...210 10 ADL 13 62 599 75 60 77 EXH09HL1W outdoor EXH12HL1W outdoor ...
Страница 28: ...210 10 ADL 28 62 599 75 60 77 BOTTOM VIEW ...
Страница 37: ...210 10 ADL 37 62 599 75 60 77 H6 Malfunction Flowchart ...