210-10 ADL
35/62
599 75 60-77
F1,F2 Malfunctions:
Flowchart
:
Start
Is the wiring terminal between
temperature sensor and the controller
loosened or poorly contacted?
Insert the
temperature
sensor tightly
Yes
Malfunction is
eliminated
Is there short circuit due to
tri-pover of the parts?
No
No
Make the parts
upright
Malfunction is
eliminated
Is the temperature sensor
normal according to the
Resistance Table?
Yes
No
No
Replace it with a
temperature sensor
of the same model
Malfunction is
eliminated
Replace the
controller with
one of the same
model
No
Yes
No
End
Yes
Yes
Yes
Содержание EXH09HL1W