210-10 ADL
22/62
599 75 60-77
Timer Change
Although timer has been set, the unit still can be turned on/off by pressing ON/OFF button of the remote controller. You can also
set the timer once again, and then the unit will operate according to the last setting.
If timer ON and timer OFF are set at the same time during operation of the unit, the unit will keep operating at current status till
OFF time reaches.
If timer ON and timer OFF are set at the same time at unit OFF, the unit will keep off status till ON time reaches.
Each day in future, the system will operate according to preset mode till OFF time reaches and stop operation till ON time
reaches. If ON time and OFF time are the same, OFF command takes the priority.
(2) Auto Button
If this button is pressed, the unit will operate in AUTO mode and indoor fan will operate at auto speed; meanwhile, the swing
motor operates. Press this button again to turn off the unit.
(3) Buzzer
Upon energization or availably operating the unit or remote controller, the buzzer will give out a beep.
(4)Sleep Function
In SLEEP mode, the unit will automatically select appropriate sleep curve to operate according to different temperature setting.
(5) Turbo Function
This function can be set in cooling or heating mode to quickly cool or heat the room.
(6) X-fan Function
①
X-fan function can be set in cooling or drying mode (X-fan function is unavailable in auto, heating or fan mode). When X-fan is
ON, after pressing ON/OFF button to turn off the unit, indoor fan will still operates at low fan speed for 10 minutes before turn off
the complete unit. Within 10 minutes, swing operates at original status, cold plasma and electrostatic dedusting is ON, while
other loads are OFF. When X-fan is OFF, press ON/OFF button to turn off the complete unit.
②
During X-fan operation, after pressing X-fan button, indoor fan stops operates immediately. Horizontal louver will close and
cold plasma and electrostatic dedusting is OFF as well.
(7) Control of Indoor Fan
Indoor fan can be set at quiet, north 1, north 2, notch 3, notch 4, notch 5 and turbo. Meanwhile, the fan can operate at low speed,
medium speed, high speed or turbo.
It can also set at auto fan speed. When indoor fan operates in auto fan speed mode, the indoor fan will operate at high speed,
medium speed, low speed or turbo according to the change of ambient temperature.
①
In auto heating mode or normal heating mode, the auto fan speed operates according to below mode:
When Tamb.
<
Tpreset-3
℃
, indoor fan operates at high speed;
When Tpreset-3
℃
≤Tamb.
<
Tpreset
+
2
℃
, indoor fan operates at medium speed;
When Tpreset
+
2
℃
≤Tamb.
<
Tpreset
+
4
℃
, indoor fan operates at low speed;
When Tamb.≥Tpreset
+
4
℃
, indoor fan operates at quiet mode.
Control drawing of auto fan in heating mode:
②
Fan mode, cooling mode: In auto cooling mode or normal cooling mode, auto fan speed operates according to below mode:
When Tamb.≥Tpreset
+
3
℃
, indoor fan operates at high speed;
Содержание EXH09HL1W
Страница 2: ...2010 10 ADL 2 62 599 73 60 74 ...
Страница 5: ...210 10 ADL 5 62 599 75 60 77 2 ESD Requirements ...
Страница 6: ...210 10 ADL 6 62 599 75 60 77 ...
Страница 13: ...210 10 ADL 13 62 599 75 60 77 EXH09HL1W outdoor EXH12HL1W outdoor ...
Страница 28: ...210 10 ADL 28 62 599 75 60 77 BOTTOM VIEW ...
Страница 37: ...210 10 ADL 37 62 599 75 60 77 H6 Malfunction Flowchart ...