background image

English

中文

操作說明書
空調器

2-19

在操作空調器前,請細讀此操作說明,並保存此書以備日後參
考。
安裝前,安裝人員應: 
閱讀安裝說明,並要求顧客保留此安裝説明以備將來參考。
取出包裝在室内機箱子的遙控器。
如果將本空調器轉讓給新的用戶或送往回收廠,請務必將
本説明書一并交出。

Operating Instructions
Air Conditioner

20-37

Before operating the unit, please read these operating 
instructions thoroughly and keep them for future reference.
Before installation, the installer should:
Read the Installation Instructions, then request the customer 
keep them for future reference.
Remove the remote control packed with the indoor unit.
If the equipment is transferred to a new user or delivered 
to a recycling plant, be sure also to hand over the manual. 

Model No.
Indoor Unit

Outdoor Unit

CS-YU18ZKA
CS-YU24ZKA 

CU-YU18ZKA
CU-YU24ZKA

Operating Instructions

Air Conditioner

ACXF55-33880

Содержание CS-YU18ZKA

Страница 1: ...er should Read the Installation Instructions then request the customer keep them for future reference Remove the remote control packed with the indoor unit If the equipment is transferred to a new use...

Страница 2: ...ET TIMER CANCEL OFF ON TEMP OFF ON SLEEP AIR CONDITIONER MODE POWERFUL FAN SPEED QUIET ON OFF TIMER CANCEL SLEEP AIR CONDITIONER POWERFUL FAN SPEED QUIET B A 3 OP EN 2 1 1 2 AAA R03 3 A 1 5 12 am pm 2...

Страница 3: ...3 B 2 MODE DRY AUTO COOL 1 OFF ON OFF ON POWER ON 3 TEMP UP TEMP DOWN TEMP 16 0 C 30 0 C 60 F 86 F 10 C F 4 11 12 13 14 15 16 18 19 AAA R03 2 2 Panasonic...

Страница 4: ...4...

Страница 5: ...5 ON Ni Cd ELCB RCD ELCB BS...

Страница 6: ...6 R32 Amin m Amin m A R32 R410A R22 R32 R22 R32 R22 R32 R410A R32 R410A R32 R410A R22 R32 R410A 1 2 R32 R410A AHU a b c d...

Страница 7: ...7 e f g h i j 5 0 25 1 04 MPa 4 15 MPa 1 A Amin m 12 2 2 1 2 2 2 2 2 8 2 2...

Страница 8: ...8 2 3 2 4 CO2 2 5 2 6 2 7 2 8...

Страница 9: ...9 6 7 5 1 04 MPa 4 15 MPa 0 25 LFL 25 8 3 4 5...

Страница 10: ...10 10 a b c d e f g h 80 i j k 11 8 OFN OFN OFN OFN 9 OFN 7...

Страница 11: ...11 12...

Страница 12: ...12 ON OFF SET TIMER CANCEL OFF ON TEMP OFF ON MODE SLEEP AIR CONDITIONER POWERFUL FAN SPEED QUIET POWER TIMER 20 POWERFUL FAN SPEED QUIET FAN SPEED AUTO FAN QUIET FAN SPEED QUIET AIR SWING...

Страница 13: ...13 SLEEP POWERFUL FAN SPEED QUIET POWERFUL 0 5 1 2 3 4 5 6 7 8 9 OFF 0 0h ON OFF SET TIMER CANCEL 1 2 3 1 TIMER ON TIMER OFF 22 00 OFF OFF 2 3 SET ON OFF CANCEL ON OFF SET 2 SLEEP...

Страница 14: ...14 AUTO POWER COOL DRY COOL 26 0 C 28 0 C 79 F 82 F COOL DRY COOL DRY C F DBT WBT DBT WBT COOL 32 89 6 23 73 4 46 114 8 26 78 8 16 60 8 11 51 8 16 60 8 11 51 8 DBT WBT...

Страница 15: ...15 2 A B 1 B A 2 1 3 4 2 2 CZ SA31P H 99 pH 7 40 C 104 F...

Страница 16: ...16 POWER TIMER ON 15 TIMER ON COOL...

Страница 17: ...17 AUTO OFF ON 1 2 AUTO OFF ON AUTO 3 AUTO OFF ON 5 COOL 4 AUTO OFF ON 5 AUTO OFF ON COOL 15 COOL 8 C 14 4 F...

Страница 18: ...2 H 14 H 15 H 16 CT H 17 H 19 H 21 H 23 1 H 24 2 H 25 H 26 ION H 27 H 28 1 H 30 H 31 H 32 2 H 33 H 34 H 35 H 36 H 37 H 38 H 39 H 41 H 50 H 51 H 52 H 58 H 59 H 64 H 67 nanoe H 70 H 71 H 72 H 85 H 97 H...

Страница 19: ...19 Pb...

Страница 20: ...R CONDITIONER MODE POWERFUL FAN SPEED QUIET ON OFF TIMER CANCEL SLEEP AIR CONDITIONER POWERFUL FAN SPEED QUIET B A Inserting the batteries 3 OP EN 2 1 1 Pull out the back cover of remote control 2 Ins...

Страница 21: ...tion POWER When the unit is ON disappears from the remote control display 3 Press TEMP UP TEMP DOWN to select the desired temperature TEMP Up Down Selection range 16 0 C 30 0 C 60 F 86 F Press for app...

Страница 22: ...plosive or flammable atmosphere Failure to do so could result in fire Do not insert your fingers or other objects into the air conditioner indoor or outdoor unit rotating parts may cause injury Do not...

Страница 23: ...fire Prevent electric shock by switching off the power supply and unplug Before cleaning or servicing When extended non use or During abnormally strong lightning activity CAUTION Indoor unit and outd...

Страница 24: ...eal the opening by pinching taping etc Handling of R32 is similar to R410A Operation maintenance repairing and refrigerant recovery should be carried out by trained and certified personnel in the use...

Страница 25: ...the precautions in 12 and comply with national regulations Always contact to local municipal offices for proper handling 2 Servicing 2 1 Service personnel The system is inspected regularly supervised...

Страница 26: ...ernally into the atmosphere 2 7 Checks to the refrigerating equipment Where electrical components are being changed they shall be fit for the purpose and to the correct specification At all times the...

Страница 27: ...the atmosphere from a leak 5 Cabling Check that cabling will not be subject to wear corrosion excessive pressure vibration sharp edges or any other adverse environmental effects The check shall also t...

Страница 28: ...minimize the amount of refrigerant contained in them Cylinders shall be kept in an appropriate position according to the instructions Ensure that the refrigerating system is earthed prior to charging...

Страница 29: ...employed Ensure that the correct number of cylinders for holding the total system charge are available All cylinders to be used are designated for the recovered refrigerant and labelled for that refri...

Страница 30: ...ation is automatically stop after 20 minutes Press the button again to cancel POWERFUL exit setting Indicators POWER TIMER Do not adjust the flap by hand For details operation refer To Learn More Uppe...

Страница 31: ...n has the priority over OFF timer This operation can be cancelled by pressing the respective button until the sleep timer reaches 0 0h To set the timer ON OFF SET TIMER CANCEL 1 2 3 1 Select TIMER ON...

Страница 32: ...fixed at middle position setting Once the temperature is achieved the horizontal flap swings up down automatically In COOL DRY mode The horizontal flap swings up down automatically Auto restart contr...

Страница 33: ...d fans should be cleaned periodically by an authorised dealer Front panel Wash gently and dry How to remove front panel 2 Slide the front panel to right A and pull out B 1 Raise up B A Close it secure...

Страница 34: ...n the discharged cold air may condense to water vapour Outdoor unit emits water or steam During cooling operation condensation occurs on cold pipes and the condensed water may drip from the outdoor un...

Страница 35: ...e AUTO OFF ON on the unit to select COOL mode For details refer The remote control is missing or a malfunction has occurred above After 15 minutes of operation it is normal to have the following tempe...

Страница 36: ...heat sink temperature sensor abnormality H 35 Indoor outdoor water adverse current abnormality H 36 Outdoor gas pipe temperature sensor abnormality H 37 Outdoor liquid pipe temperature sensor abnorma...

Страница 37: ...be used in combination with a chemical symbol In this case it complies with the requirement set by the Directive for the chemical involved WARNING This symbol shows that this equipment uses a mildly f...

Страница 38: ...Memo...

Страница 39: ...Memo...

Страница 40: ...Printed in Malaysia Panasonic Corporation 1006 Oaza Kadoma Kadoma City Osaka 571 8501 Japan Website http www panasonic com Panasonic Corporation 2022 ACXF55 33880 SS1022 0...

Отзывы: