64
Installation manual
23 Air vent connection
The air vent of the outer drum opens on the top of the machine. Connect the connection bellow
⌀
60 to this opening.
Connect the air vent, to the outside of the laundry in accordance with the legislation.
The air vent should resist to 100 °C (212 °F) temperature and allow the condenses to return to the machine.
24 Feeder cable sections
The feeder cable sections mentioned in our literature are given only as a guide.
To obtain a value perfectly suited to your own application and which takes account of the different correction factors
in respect of your plant, refer to the tables below.
Table 1 (in accordance with EN Standard 60204-1)
Values given for:
• Cable with copper conductors
• Cable with PVC insulation (for other insulants see Table 3)
• Ambient temperature 40°C max. (for others see Table 2)
• Three-phase cable under load without including starting currents
• BT / C/ E cable layout.
Maximum Admissible Current
Cable section
Seated in Cable Duct or
Cable trough
Wall fixing
Cable tray
B2
BC
E
3 x 1.5 mm²
12.2 A
15.2 A
16.1 A
3 x 2.5 mm²
16.5 A
21 A
22 A
3 x 4mm²
23 A
28 A
30 A
3 x 6 mm²
29 A
36 A
37 A
3 x 10 mm²
40 A
50 A
52 A
3 x 16 mm²
53 A
66 A
70 A
3 x 25 mm²
67 A
84 A
88 A
3 x 35 mm²
83 A
104 A
114
3 x 50 mm²
-
123 A
123 A
3 x 70 mm²
-
155 A
155 A
Содержание WB6-20
Страница 1: ...Installation manual Washer extractors WB6 20 WB6 27 WB6 35 Original instructions 05201148 EN ...
Страница 2: ......
Страница 25: ...Installation manual 25 Back view Right view Drain connection Top view ...
Страница 31: ...Installation manual 31 Important Never handling the machine without the transportation bridles ...
Страница 47: ...Installation manual 47 No Barrier washer Barrier washer ...
Страница 49: ...Installation manual 49 Front view Side view Top view Gas exchanger with draught accelerator ...
Страница 62: ...62 Installation manual ...
Страница 71: ......
Страница 72: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...