Installation manual
59
TABLE OF CORRESPONDENCES — Washer-Extractor WB6–27
Category
index
Type of
gas
Working
supply
pressure
in mbar
Hi in MJ/m
3
Ø of injec-
tors in mm
Pressure
at injectors
in mm H
2
O
Heat
emission
Qn in kW
(Hi)
Consump-
tion
Mn in kg/h
(Hi)**
Consump-
tion
Vn in m
3
/
h**
*2E, 2H,
2ESI
G20
20
34.02
2.90
153
40
-
0.90
2L, 2ESI
G25
25
29.25
3.20
154
40
-
1.05
3P
G31
37
46.34
1.85
regulator
out of
operation
40
0.66
-
3P
G31
50
46.34
1.70
regulator
out of
operation
40
0.66
-
*For Belgium, no work is allowed between G20 and G25.
** normal cycle : prewash 3 min at 35 °C, drain. 2 min, main wash 4 min at 65 °C, drain 2 min, rinse 2 min, extract. 2
min, rinse 2 min, extract 2 min, rinse 2 min, extrac. 10 min (cold water supply at 15 °C).
Note!
G20 (H) = natural gas, Lacq type (20 mbar)
G25 (L) = natural gas, Groningue type (20 or 25 mbar)
G31 = propane gas (28/30, 37, 50 mbar)
TABLE OF CORRESPONDENCES — Washer-Extractor WB6–35
Category
index
Type of
gas
Working
supply
pressure
in mbar
Hi in MJ/m
3
Ø of injec-
tors in mm
Pressure
at injectors
in mm H
2
O
Heat
emission
Qn in kW
(Hi)
Consump-
tion
Mn in kg/h
(Hi)**
Consump-
tion
Vn in m
3
/
h**
*2E, 2H,
2ESI
G20
20
34.02
2.90
153
40
-
1.30
2L, 2ESI
G25
25
29.25
3.20
154
40
-
1.50
3P
G31
37
46.34
1.85
regulator
out of
operation
40
0.95
-
3P
G31
50
46.34
1.70
regulator
out of
operation
40
0.95
-
*For Belgium, no work is allowed between G20 and G25.
** normal cycle : prewash 3 min at 35 °C, drain. 2 min, main wash 4 min at 65 °C, drain 2 min, rinse 2 min, extract. 2
min, rinse 2 min, extract 2 min, rinse 2 min, extrac. 10 min (cold water supply at 15 °C).
Note!
G20 (H) = natural gas, Lacq type (20 mbar)
G25 (L) = natural gas, Groningue type (20 or 25 mbar)
G31 = propane gas (28/30, 37, 50 mbar)
Important
Tightness test after installation.
The gas leak test is performed as follows :
1. Paint pipe joints, pilot gas tubing connections and inspect outlets with rich soap and water solution ; do not
use an aggressive soap.
2. Put the machine into service. Bubbles indicate a gas leak.
3. Eliminate this leak.
Note!
After all intervention, re-seal (red varnish) the following adjustment organs:
— regulator of pressure.
In case of changing of gas, the stick for the adjustment has to be modified.
Содержание WB6-20
Страница 1: ...Installation manual Washer extractors WB6 20 WB6 27 WB6 35 Original instructions 05201148 EN ...
Страница 2: ......
Страница 25: ...Installation manual 25 Back view Right view Drain connection Top view ...
Страница 31: ...Installation manual 31 Important Never handling the machine without the transportation bridles ...
Страница 47: ...Installation manual 47 No Barrier washer Barrier washer ...
Страница 49: ...Installation manual 49 Front view Side view Top view Gas exchanger with draught accelerator ...
Страница 62: ...62 Installation manual ...
Страница 71: ......
Страница 72: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...