46
Installation manual
21 Compressed air connection
Caution
This compressed air connection is
only
for the WB6 models with one of these following options:
Clean room option
: to pilot the drain valve.
Low pressure steam heating
: to pilot steam inlet valve.
Caution
The compressed air admitted to the distributors must be purified to the following values:
• it must be free from solid particles larger than 5 µm. The filter present on our machines has a filtration of 5µm.
• It should not contain more than 1.5 g of water / m3
• It should not contain more than 30 mg of oil condensate / m3
The manual stopping valve lockable in closed position (provided by customer) should be installed on the machine's
compressed air supply.
The supply pipe should accept a pressure of at least 1 Mpa (10 bar).
Connection diameter : rapid action hose coupling DN 6 for hose Ø 6/8 mm.
Advised pressure
550-700 kPa (5.5-7 bar)
Minimum pressure
550 kPa (5.5 bar)
Maximum pressure
700 kPa (7 bar)
Consumption
10 l/h
Содержание WB6-20
Страница 1: ...Installation manual Washer extractors WB6 20 WB6 27 WB6 35 Original instructions 05201148 EN ...
Страница 2: ......
Страница 25: ...Installation manual 25 Back view Right view Drain connection Top view ...
Страница 31: ...Installation manual 31 Important Never handling the machine without the transportation bridles ...
Страница 47: ...Installation manual 47 No Barrier washer Barrier washer ...
Страница 49: ...Installation manual 49 Front view Side view Top view Gas exchanger with draught accelerator ...
Страница 62: ...62 Installation manual ...
Страница 71: ......
Страница 72: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...