Installation manual
43
19 Steam connection
For transport reasons, the steam electrovalve is dismantled and placed in the cardboard box supplies.
The inlet pipe to the machine has to be fit with a manual stopping valve to ease installation and maintenance.
Hereunder values apply to the steam pressure:
Recommended pressure: 300 at 600 kPa (3 at 6 kg/cm²) (43.5 at 87 psi)
Limiting of values:
•
mini. 100 kPa (1 kg/cm²) (14.5 psi)
•
maxi. 600 kPa (6 kg/cm²) (87psi)
Connection size: DN 20 (¾" BSP).
Assemble the set (U.P.M.V.G.F.Y) between the machine and steam piping.
S
Steam inlet
Y
Manual stop wheel valve DN 20 (¾" BSP) (provided by customer)
F
Steam filter DN 20 (¾" BSP) (provided)
G
Nipple DN 20 (¾" BSP) (provided by customer)
V
Steam electrovalve DN 20 (¾" BSP) (provided)
P
Steam special flexible pipe DN 20 (¾" BSP)(provided)
M
Insulating (provided)
U
Pipe union DN 20 (¾" BSP) (provided)
Steam connection low pressure
Caution
For this heating, you need air compressed connection to pilot the steam valve.
Hereunder values apply to the steam pressure:
Recommended pressure: 50 kPa (0.1 kg/cm²) (8 psi)
Содержание WB6-20
Страница 1: ...Installation manual Washer extractors WB6 20 WB6 27 WB6 35 Original instructions 05201148 EN ...
Страница 2: ......
Страница 25: ...Installation manual 25 Back view Right view Drain connection Top view ...
Страница 31: ...Installation manual 31 Important Never handling the machine without the transportation bridles ...
Страница 47: ...Installation manual 47 No Barrier washer Barrier washer ...
Страница 49: ...Installation manual 49 Front view Side view Top view Gas exchanger with draught accelerator ...
Страница 62: ...62 Installation manual ...
Страница 71: ......
Страница 72: ...Electrolux Professional AB 341 80 Ljungby Sweden www electroluxprofessional com ...