![Electro Industries Shark 100S Скачать руководство пользователя страница 136](http://html.mh-extra.com/html/electro-industries/shark-100s/shark-100s_installation-and-operation-manual_2379713136.webp)
B: Modbus Map
Doc# E145721 MM-6
Electro
Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Description
1
Format
Range
6
Units or
Resolution
Comments
#
Reg
Modbus Address
Hex
Decimal
753E - 753E 30015 - 30015
User Settings Flags
UINT16
bit-ma
pp
ed
---g--nn srp--wf-
g = enable alternate full scale bargra
p
h
current (1=on, 0=off)
nn = number of
p
hases for voltage &
current screens (3=ABC, 2=AB, 1=A,
0=ABC)
s = scroll (1=on, 0=off)
r =
p
assword for reset in use (1=on, 0=off)
p
=
p
assword for configuration in use
(1=on, 0=off)
w =
p
wr dir (0-view as load, 1-view as
generator)
f = fli
p
p
ower factor sign (1=yes, 0=no)
1
753F - 753F
30016 - 30016
Full Scale Current (for load % bargra
p
h)
UINT16
0 to 9999
none
If non-zero and user settings bit g is set,
this value re
p
laces CT numerator in the full
scale current calculation.
1
7540 - 7547
30017 - 30024
Meter Designation
ASCII
16 char
none
8
7548 - 7548
30025 - 30025
COM1 setu
p
UINT16
bit-ma
pp
ed
----dddd -0100110
1
7549 - 7549
30026 - 30026
COM2 setu
p
UINT16
bit-ma
pp
ed
----dddd -ppp-bbb
1
754A - 754A 30027 - 30027
COM2 address
UINT16
1 to 247
none
1
754B - 754B 30028 - 30028
Limit #1 Identifier
UINT16
0 to 65535
use Modbus address as the identifier (see
notes 7, 11, 12)
1
754C - 754C 30029 - 30029
Limit #1 Out High Set
p
oint
SINT16
-200.0 to +200.0
0.1% of full scale
Set
p
oint for the "above" limit (LM1), see
notes 11-12.
1
754D - 754D 30030 - 30030
Limit #1 In High Threshold
SINT16
-200.0 to +200.0
0.1% of full scale
Threshold at which "above" limit clears;
normally less than or equal to the "above"
set
p
oint; see notes 11-12.
1
754E - 754E 30031 - 30031
Limit #1 Out Low Set
p
oint
SINT16
-200.0 to +200.0
0.1% of full scale
Set
p
oint for the "below" limit (LM2), see
notes 11-12.
1
754F - 754F
30032 - 30032
Limit #1 In Low Threshold
SINT16
-200.0 to +200.0
0.1% of full scale
Threshold at which "below" limit clears;
normally greater than or equal to the
"below" set
p
oint; see notes 11-12.
1
7550 - 7554
30033 - 30037
Limit #2
SINT16
5
7555 - 7559
30038 - 30042
Limit #3
SINT16
5
755A - 755E 30043 - 30047
Limit #4
SINT16
5
755F - 7563
30048 - 30052
Limit #5
SINT16
5
7564 - 7568
30053 - 30057
Limit #6
SINT16
5
7569 - 756D 30058 - 30062
Limit #7
SINT16
5
756E - 7572
30063 - 30067
Limit #8
SINT16
5
Block Size:
68
same as Limit #1
same as Limit #1
same as Limit #1
dddd = re
p
ly delay (* 50 msec)
ppp
=
p
rotocol (1-Modbus RTU, 2-Modbus
ASCII, 3-DNP)
bbb = baud rate (1-9600, 2-19200, 4-
38400, 6-57600)
Содержание Shark 100S