background image

                   

39 

 

The  fault  message  can  only  be  cleared 
manually after the fault condition has been 
rectified. 

 

3.13.3. Viewing/Clearing the Fault 
Message 

To check what the fault condition is,  

Step 1.

 When the system is in Alarm off mode. 

Enter your PIN Code followed by 

OK

Step 2. 

The screen will display 

 

    F  a u  l  t    D s  p           
    A  r  m                      

 

 

 

and the cursor stays at

 Fault Dsp

 

Step 3. 

Press

 OK

 to select

 Fault Dsp 

Step 4.

 All the fault events are listed. Use 

&

 

key to move the cursor 

downwards or upwards.  The screen 
is also scrolled down or up 
respectively.       

Step 5. 

After viewing all the fault events, press 

 

key, a prompt message is displayed. 

 

    C l  e  a  r    F  a  u  l  t       
        D s  p  :    (  O K ?  )     

 

Step  6. 

Press 

OK

,  then  the fault  event,  which 

the  fault  condition  has  been  rectified, 
will be cleared and the screen returns 
to 

Alarm off

 

<

<

N

N

O

O

T

T

E

E

>

>

 

 

 

In

  Step  6

,  if 

 key  is  pressed,  the 

screen  returns  to 

Alarm  off

,  the 

Yellow  LED  stays  on,  the  Control 
Panel  keeps  sounding  a  short  beep 
every 30 seconds, and the fault event 
display retains. 

 

If  the  fault  condition  has  not  been 
rectified, the fault event display will not 
be  cleared.    It  will  come  on  again 
while  you  try  to  arm  the  system  and 
the faulty condition inhibits the system 
from  being  armed,  then  the  fault 
message will be displayed again. The 
fault event display can be cleared only 
after  the  fault  condition  has  been 
rectified. 

 

Even  when  the  fault  messgae  is 

cleared, the fault event is still retained 
in 

Log

 

3.13.4. Fault Event Response 

 

When  a  fault  condition  is  detected,  in 
addition  to  the  fault  display,  the  Control 
Panel 

will 

also 

respond 

separately 

according to the nature of the fault event. 

 

AC Power Fail / Restore

 

 

When  the  AC  power  fails,  the 

yellow  LED  will  light,  the  fault 
message  will  be  displayed  and  the 
system  will  send  a  AC  Power  Fail 
report via SMS message to the first 
telephone number.  

 

Whenever Tel number exists, and 

power  is  restored  from  complete 
power  interruption  (either  restored 
by  AC  or  battery),  the  system  will 
send  an  AC  Power  Restore  report 
via  SMS  message  to  the  first 
telephone number in 5 minutes.  

 

Control Panel Low Battery 

<

<

I

I

M

M

P

P

O

O

R

R

T

T

A

A

N

N

T

T

 

 

N

N

O

O

T

T

E

E

>

>

 

 

 

30  minutes  before  powering  on  the 
Control  Panel,  if  the  battery  switch  is 
put on OFF position, the Control Panel 
will not detect battery condition. 

 

Any time the Panel battery Low is 

detected,  the  Control  Panel  will 
report via SMS message to the first 
telephone number in 2 minutes. 

 

However, 

when 

the 

battery 

restored,  an 

L.B.  Restore 

will    be 

reported  via  SMS  message  in 
30min . 

 

Panel Sabotaged 

<

<

I

I

M

M

P

P

O

O

R

R

T

T

A

A

N

N

T

T

 

 

N

N

O

O

T

T

E

E

>

>

 

 

 

Please refer to 2.1.3.14 Tamper alarm 
under  section  General  Setting  to  set 
the tamper alarm reporting method.  

 

To  restore  the  tamper  alarm  function, 
hook  the  C-FENCCE  HOME  unit  to 
the wall mounting bracket again. Then 
place it to a desired location.  

 

 

If

  Away  Arm  Only

  is  selected 

under Tamper alarm function,  when 

Содержание CTC-909B

Страница 1: ...x C Fence Home with image verification...

Страница 2: ...__ 11 2 1 7 Walk Test____________________________________________________________________________ 22 2 2 Spc Settings____________________________________________________________________ 22 2 2 1 Super...

Страница 3: ..._____________ 32 3 6 6 Arming with MMS Transmission_________________________________________________________ 32 3 7 Alarm Off Mode _________________________________________________________________ 33...

Страница 4: ..._________________________________________________ 50 4 1 Device Naming __________________________________________________________________ 50 4 2 Reset Procedure _______________________________________...

Страница 5: ...display upwards 6 Key In Programming mode press this key to move the cursor and scroll the display downwards 7 Key In Programming mode use this key for deleting a digit canceling the selection abortin...

Страница 6: ...ol Panel The easiest way to get to know the system and get it up and running quickly is to get all the devices and accessories programmed on a tabletop before locating and mounting them The Control Pa...

Страница 7: ...ttery are both off then the changes will not be saved Step 1 Find a suitable location for the Control Panel to be installed Step 2 Apply the AC Power You will hear one long beep Alarm On will be displ...

Страница 8: ...S M Step 6 Move the cursor to the desired item and press OK to confirm the selection The display will show you the individual programming screen accordingly N NO OT TE E If a down arrow symbol V appe...

Страница 9: ...when the Latch selection function is enabled See section 2 2 2 under Configuring your system The latch reporting function can be set respectively for each Pin code Latch Report ON Whenever the system...

Страница 10: ...then press OK the following screen is displayed D e l e t e p i n c o d e O K Step 3 Press OK and the screen returns to previous one with the deleted User PIN code marked with 2 1 1 2 Duress Code The...

Страница 11: ...ec is set as factory default 2 1 3 2 A Exit Timer Away Exit Timer While the system gets into Away arm mode by Control Panel Remote Controller RC or Remote Keypad KP an Away exit timer starts counting...

Страница 12: ...beep and Off no beep Low is set as factory default 2 1 3 8 H Exit Sound Home Exit Sound This is for you to decide whether the Control Panel sounds count down beeps and volume of beep during the Home...

Страница 13: ...ed o O n O f f On Local Siren On is set as factory default When the Control Panel receives an effectual triggered signal its siren raises alarm Off Local Siren Off means when the Control Panel receive...

Страница 14: ...Control Panel e g when the BX s alarm length is set as 3 mins and the panel s alarm length is set as 1 min both alarm siren stop at 1 min when alarm is triggered however the BX s LED keeps flashing un...

Страница 15: ...ons 1 1 2 2 A B C a b c 3 3 D E F d e f 4 4 G H I g h i 5 5 J K L j k l 6 6 M N O m n o 7 7 P Q R S p q r s 8 8 T U V t u v 9 9 W X Y Z w x y z 0 0 space Delete character and backspace Set SMS Header...

Страница 16: ...ss OK to continue the learning process Another prompting message will be displayed for you to select its zone number Step 5 All the non occupied zones zones which have no device added in yet will be d...

Страница 17: ...is triggered the Control Panel will not respond E for Entry Door Contact When the system is in Away arm Home arm mode if Entry Door Contact is triggered the Control Panel will start an entry period to...

Страница 18: ...name followed by OK or just press OK for no name Please see section Device Naming for details E n t e r N a me O k StepC8 Press OK when finished and the display will show the new zone name next to the...

Страница 19: ...code of KP 9 0000 is set as factory default followed by the key A long beep will be performed on KP 9 with the active Green LED turned on Step 2 Put the Control Panel in Add Device mode The following...

Страница 20: ...ptured images of IP camera CTC 1816 CTC1816 BASIC in the configuration webpage of C FENCCE HOME To view imaged captured please access the configuration webpage of CTC 1816 CTC 1816 Basic for details D...

Страница 21: ...4 seconds seperately Home Accesss IR Camera When the system is in Away Arm mode if Home Access IR Camera is triggered the camera will be activated immediately and take the 1st photo immediately and th...

Страница 22: ...l E mg Wa t e r If no changes is wished here press to skip to Step3A Step2A Use keys to scroll the display and choose the desired device attribute by pressing OK The screen will show Z o n e T y p e O...

Страница 23: ...splayed for you to reconfirm R e mo v e O k R C M R S M I T H Step 3 Press OK key Deleting a device is now completed N NO OT TE E If the selected sensor zone is not what you want to delete press to ex...

Страница 24: ...enabled with Tamper protection simultanously N NO OT TE E Siren tamper disable will automatically revert to On after an hour if it is not switchd back remotely Confirm On Confirm Off This is to enabl...

Страница 25: ...en system is armed Day Home PSS will turn off When set as NO and system is disarmed PSS will turn on When system is armed Day Home PSS will turn on Set Unset N When set as NC and system is disarmed PS...

Страница 26: ...g R e c o r d s Press OK Key Wr i s t T X R 0 9 Use key can look through previous RF record Press key once again The screen will show A r e y o u s u r e T o q u i t Press key back to log record Press...

Страница 27: ...y affect later settings of PIN code RC NS and KP but it will not overwrite any previousely change made in Optional Latch 2 2 3 Remote Controller Entry Enable Select RC Ent E This is to Turn On or Off...

Страница 28: ...ress OK key to enter the phone number E n t e r n e w N o O K Step 3 Key in desired phone number Step 4 Press OK to confirm your setting N NO OT TE E The maximum length of a number is 30 digits includ...

Страница 29: ...M S A P N P WD M M S A P N U R L M M S P R O X Y A D D R M M S P R O X Y P O R T 2 3 3 1 MMS APN The MMS APN is offered by your SIM card service provider supplier accordingly Specify a MMS APN name M...

Страница 30: ...der for your APN When APN is set the system will be valid for internet connection A P N E D I T O R _ Step 1 Enter your APN max 31 digits alphabets The keys have the following functions Step 2 Select...

Страница 31: ...n k n o w n 2 4 2 GSM Reset GSM module will be reset once OK is pressed with 30 sec of time out period G S M R e s e t i n g 0 4 2 S e c N NO OT TE E If the screen automatically returns to the Progra...

Страница 32: ...first line of the line of the list for indication N NO OT TE E If arming the system is wished please refer to section Forced Arming below After 2 mins of key inactivity the system will automatically e...

Страница 33: ...he system will operates differntly according to its natural of Attribute 3 3 Home Arm The Home Arm Mode allows the home to be Partial Armed Thus part of the System is protected with the Alarm yet the...

Страница 34: ...onth and end month must be set completely Start Month Step 1 Select Start Month section and press OK S t a r t M o n t h J a n V O K Step 2 Use keys to choose the daylight starting month and press OK...

Страница 35: ...red automatically When a sensor is bypassed the system can be Armed directly regardless of its fault situation if any However its fault situation is still being monitored logged and displayed when you...

Страница 36: ...y pass it or permanently remove it The force arming record can be checked in the Log section 3 6 3 Arming with Door Opened While arming the system if any Door Contact detected as Open the Control Pane...

Страница 37: ...layed in reversed order i e most recent event first The log is marked with a Start label before the most recent entry and End after the oldest entry To View the Event Log Step 1 When the system is und...

Страница 38: ...reporting sequence is SMS MMS Step3 After the C FENCCE HOME completes reporting the IR Camera will restart the detection N NO OT TE E If more than one CTC 852 cameras are triggered those triggered CT...

Страница 39: ......

Страница 40: ...rt Entry Timer No Response No Response No Response Away Entry P Door Chime Start Entry Timer No Response No Response No Response No Response No Response No Response 24 HR H Instant Burglar Alarm Insta...

Страница 41: ...ow you the device that triggered the alarm with its zone number is displayed A l a r m S t a r t e d b y 0 1 I R H a l l w a y If there is more than one alarm events have been raised the Control Panel...

Страница 42: ...us without sending report If no valid user PIN code is entered a burglar alarm will be sent 3 12 2 Mis Operation Reporting Automatically with latchkey reporting Latch Rpt being set to On all Arm Home...

Страница 43: ...CE HOME will detect interference only on the 868Mhz band After a continuous interference signal is present for more than 30 seconds an interference event can be logged reported and displayed on the LC...

Страница 44: ...fied Even when the fault messgae is cleared the fault event is still retained in Log 3 13 4 Fault Event Response When a fault condition is detected in addition to the fault display the Control Panel w...

Страница 45: ...ered while the system is in Arm mode the Control Panel will sound an audible alarm and report Burglar Alarm Sensor Tamper Open via SMS message to the first telephone number While if the system is in A...

Страница 46: ...ow battery N NO OT TE E While you arm the system if any of Door Contact or PIR is triggered arming is also prohibited and the sensor triggered will be displayed as fault message Sensor triggered Messa...

Страница 47: ...ge You can send it to the panel Step 10 Wait for the panel to send back a confirmation message The format will be Confirmation SMS keyword PIN Code Control Command 00 Only when the Control Unit receiv...

Страница 48: ......

Страница 49: ...isplay by entering backward spaces and pressing OK 4 2 Reset Procedure Reset to Factory Default Setting The Control Panel can clear all programmed parameters by the following sequence 1 Power down the...

Отзывы: