7
Programming mode.
Factory default:
1111
To set/change the Master Code, follow
the same steps as those to set
/change/delete the user PIN code
described in previous section.
2.1.3 Panel Setting
A . E n t r y t i m e r
A . E x i t t i m e r
H . E n t r y t i m e r
H . E x i t t i m e r
A . E n t r y s o u n d
A . E x i t s o u n d
H . E n t r y s o u n d
H . E x i t s o u n d
D o o r c h i m e
W a r n i n g b e e p
M o b i l i t y
L o c a l s i r e n
I n t e r f e r e n c e
T a m p e r a l a r m
A l a r m l e n g t h
S i r e n d e l a y
F i n a l d o o r
V e r i f i c a t i o n
2.1.3.1 A. Entry Timer (Away Entry
Timer)
When Door Contact (DC) or PIR Detector (IR)
is set as
Entry / Away Entry
attribute, the
system gets into counting down period (Away
entry timer) while the DC or IR is triggered
under Away arm mode.
During the counting down period, it is allowed
to use correct PIN code to disarm the alarm
and the alarm reporting will not be sent. On the
other hand, if the correct PIN code has not
been entered within the period, Control Panel
raises an alarm and sends an alarm report.
Options available are disable (alarm
immediately) , 10 sec., 20 sec., up to 70
sec. in 10-sec increments.
Press
OK
on A. Entry Timer and the
following screen will be displayed:
D i s a b l e
1 0 s e c
o 2 0 s e c
3 0 s e c
4 0 s e c
5 0 s e c
6 0 s e c
7 0 s e c
20 sec.
is set as factory default.
2.1.3.2 A. Exit Timer (Away Exit Timer)
While the system gets into Away arm mode by
Control Panel, Remote Controller (RC) or
Remote Keypad (KP), an Away exit timer starts
counting down.
During the counting down period, pressing the
Arm Button of the RC can restart the counting.
In addition, it is allowed to use correct PIN
code or press Disarm Button of the RC to stop
the counting and return to Alarm off mode.
Options available are Disable (exit timer
prohibited), 10 sec., 20 sec. up to 70 sec.
in 10-sec increments.
30 sec.
is set as factory default.
2.1.3.3 H. Entry Timer (Home Entry
Timer)
When Door Contact (DC) or PIR Detector (IR)
is set as
Entry / Home Access
attribute, the
system gets into counting down period (Home
entry timer) while the DC or IR is triggered
under Home arm mode.
During the counting down period, it is allowed
to use correct PIN code to disarm the alarm
and the alarm reporting will not be sent. On the
other hand, if the correct PIN code has not
been entered within the period, Control Panel
raises an alarm and sends an alarm report.
Options available are disable (alarm
immediately) , 10 sec., 20 sec., up to 70
sec. in 10-sec increments.
20 sec.
is set as factory default.
2.1.3.4 H. Exit Timer (Home Exit Timer)
While the system gets into Home arm mode by
Control Panel, Remote Controller (RC) or
Remote Keypad (KP) or Night Switch(NS), an
Away exit timer starts counting down.
During the counting down period, pressing the
Home Button of the RC can restart the
counting. In addition, it is allowed to use