selected, the system sends tamper-
triggered report to Central Monitoring
Station in all modes while tamper is
triggered.
<
<
N
N
O
O
T
T
E
E
>
>
After the status of IR Camera
Tamper or Tilt Switch is restored,
IR camera won
’t detect the status
of Tamper and Tilt Switch for 5
minutes. After 5 minutes, IR
camera will continue reporting
tamper status to the Control Panel.
2.3.3.15 Alarm Length
This is for you to select the built-in siren
duration when an alarm is activated. Options
are disable (no siren alarm) and 1-min to 15-
min in 1- min increments.
D i s a b l e
1 M i n
2 M i n
o 3 M i n
4 M i n
5 M i n
to
1 5 M i n
3 minutes is set as factory default.
If
Disable
is selected, when the Control
Panel receives alarm signal, the panel
siren, Bell Box (BX) will not raise an alarm
sounding.
If 1~15 min is selected and the local siren
function is disabled (see section 2.3.3.12
above), the panel siren will not raise an
alarm when alarm is triggered. However,
the BX will raise siren based on your
programming (see the operation manual of
BX).
If BX
’s alarm length is longer than the
Control Panel
’s, the system gives priority
to the Control Panel. (e.g. when the BX
’s
alarm length is set as 3 mins, and the
panel
’s alarm length is set as 1 min, both
alarm siren stop at 1 min when alarm is
triggered; however, the BX
’s LED keeps
flashing until 3 mins is expired.
2.3.3.16 Siren Delay
This is for you to decide how long should the
Control Panel suppress the audible alarms
after a Burglar or Entry alarm is reported.
Options are disable and 1-min delay to 10-min
delay in increments of 1 minute
o D i s a b l e
1 M i n
.
.
.
1 0 M i n
Disable
is set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
Some audible alarm will not be
delayed (disregard its siren delay
setting) when the following cindition
detected:
Fire alarm
Water alarm
Personal panic alarm
Medical emergency
Tamper alarm
GSM/GPRS failure
The alarm reporting will be sent
immedicately, even if the audible
alarm is delayed.
2.3.3.17 Final Door
When the system is under away arming (see
section 4.2.1) with Final Door set to On and a
Door Contact set as Entry device, then, the
system will automatically full arm the system
once this Door Contact is detected as closed,
event if the count-down period is not yet
complete.
o F i n a l d o o r O n
F i n a l d o o r O f f v
Final Door On
(Final Door Set Option On)
is set as factory default.
2.3.3.18 Verification
This is use to set the Sequential Verification
Reporting.