22
L e a r n i n g p r o c e s s
w a s f i n i s h e d
<
<
N
N
O
O
T
T
E
E
>
>
If this message does not appear,
please repeat steps 1-7.
Step 9.
The system will then return to channel
menu automatically.
2.1.7. Walk Test
When
Walk Test
is selected, the
Bule
& Yellow LED’s will flash 3 secs
with 3 beeps, and the following two
test patterns are displayed for 2 sec.
each.
Then the following message is
displayed:
* W a l k T e s t *
Pressing the test button on the
sensor or any button on the Remote
Controller or triggering the sensor, if
the Control Panel received the signal,
it will sound a 2-tone beep and the
display will show you which sensor
with its zone number that is reacting.
I R Z o n e 0 2
H a l l w a y R = 9
The message will be displayed for 30
sec. or being replaced by another
test signal.
Pressing OK key or after 30 sec , the
screen will return to Walk Test banner.
Log of Walk Test
To watch the log of
Walk Test
, press
key. The screen will display:
T o d i s P l a y
T e s t i n g R e c o r d s
Press
OK
Key
W r i s t T X
. . . . . . . . . R = 0 9
Use
&
key can look through
previous RF record.
Press
key once again. The screen
will show:
A r e y o u s u r e
T o q u i t ?
Press
key back to log record.
Press OK key to enter Area selection
menu.
In the Install mode/programming
mode, if no test signals are received
for 5 minutes, the Control Panel will
exit
Walk Test
mode and return to
Alarm Of
f. Press
OK
key to add
another 5 minutes.
In the user operation mode, if no test
signals are received for 2 minutes,
the Control Panel will exit
Walk Test
mode and return to
Alarm Of
f. Press
OK
key to add another 2 minutes.
2.2. Spc. Settings
o S u p e r v i s i o n
L a t c h s e l e c t i o n
R C E n t E s e l .
G S M B a n d s e l .
2.2.1. Supervision
This option is used to enable system
supervision function. When
ON
is selected, C-
FENCCE HOME will be able to receive the
check-in signals from the devices to indicate
their proper functioning.
D i s a b l e
4 H o u r s
6 H o u r s
8 H o u r s
1 2 H o u r s
2 4 H o u r s
PIR sensor, Door Contact, Water Sensor
or IR
Camera
or Smoke Sensor, after installed, will
transmit a periodic supervision signal at
intervals between 30 min. to 50 min.