23
If the Control Panel dose not receive the
signals transmitted from an individual sensor
for a period of 4 Hours, 6 Hours, 8 Hours, 12
Hours, or 24 Hours, a
sensor out-of-order
fault event will be detected.
Disable
is set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
For IR Camera (CTC-852), except the
Supervision way mentioned above,
please refer to IR Camera (CTC-852
Supervision Chart.
2.2.2. Latch Selection
Latch report
is sent while system mode is
changed (e.g. from Away arm mode to Alarm
off mode) and can be applied to control prompt
situation from the system.
This function is to program whether Control
Panel send latch key report while the system
mode is changed.
o O p t i o n a l L a t c h
L a t c h O f f
L a t c h O n
Latch On
is set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
When the Latchkey Reporting feature
is chosen
Optional Latch
, the
system will ask your option for latch
report while you program DC Attribute
Set/Unset, Pin code and temporary
code and while you learn RC, NS and
KP in the Control Panel.
When the Latchkey Reporting feature
is chosen
OFF
, the system does not
inform all arming and disarming
actions of all users, the RC, NS and
KP to Central Monitoring Station or
users.
When the Latchkey Reporting feature
is chosen
ON
, the system informs all
arming and disarming actions of all
users and the RC, NS and KP to
Central Monitoring Station or users.
The “
Latch ON/OFF
” will only affect
later settings of PIN code, RC, NS and
KP, but it will not overwrite any
previousely
change
made
in
“
Optional Latch
”
2.2.3. Remote Controller Entry Enable
Select (RC Ent E)
This is to Turn On or Off the Remote Controller
disarm function.
R C E n t E O p t
R C E n t E O n
R C E n t E O f f
RC Ent E On (Remote Controller Entry
Enable On)
is set as factory default.
<
<
N
N
O
O
T
T
E
E
>
>
When selected as
On
or
Off
, all new
leant Remote Controller will use the
same setting. During the learning
process, an option to turn On or Off
Remote Controller Entry will not be
shown.
When selected as
Opt (Option)
, when
new Remote Controllers, an option to
turn On or Off Remote Controller
Entry will be shown.
Changing the Remote Controller Entry
Enable Select settings will not affect
the previous learnt Remote Controller
settings saved in the Control Panel.
When
RC ENT E Off
(Remote
Controller
Entry
Enable
Off)
is
selected, it is not possible to disarm
the Control Panel when the system is
fully armed.
The feature is used to ensure that the
system cannot be disarmed with a
stolen
Remote
Control
without
unlocking a door first.
When
RC ENT E On
(Remote
Controller
Entry
Enable
On)
is
selected, the Remote Controller can
arm and disarm the control panel as
normal without activating an entry
point.
However, when an alarm is triggered
by the panic buttion on the RC, it is
prohibited to use the same RC to
disarm.
2.2.4. GSM Band Select
Depending on your local telecom service
provider
’s network setting, you will need to
adjust the GSM band setting accordingly.
Please check with our local telecom service