Beginning EL Rates
- Set the starting times of 2 different tariffs rates. This is important for proper
information of consumpted electricity!
Solar Protection
(
NHPC-V4-2 only
) Menu for setting the solar
installation protection mode. Set parameters:
Auto Holiday mode
– When this field is checked, it is
allowed to automatically switch on the mode for
discharging heat from the boiler at night – “Vacation”.
Thanks to this discharging, the solar installation will be
protected from overheating in the strong sun on the next
day, by transferring heat to the already cooled water in
the boiler. Vacation Mode is extremely useful if you
have to spend a lot of time away from home and do not
use hot water
Tank min temp.
– If accumulated heat discharge is
activated with mode Vacation, the boiler temperature
will be reduced to the value set in this field
Solar anti-forst
– Allows activation of mode for protection
aganst freezing of the solar.
Anti-frost temp.–
Sets the temperature, below which is
activated the mode for protection of the solar collector
against freezing, if the mode is allowed.
Solar overheating–
Sets the temperature, at which is
activated the alarm for overheating of the solar
collector.
System Settings
- The
Light
field adjusts the brightness of
the display. Field "
Anode
“ will define the presence of Anode
Protection (if the boiler is made of stainless steel, there is no
anode protection). The "
Power
" field adjusts the power of the
power heater. By default, parameters for a boiler with a 2KW
heater and presence of anode protection are set. The next
field activates the
Anti-legionella
mode. It ensures that the
boiler is heated up to 70 ° C at least once a week. This is done
in order to prevent the development of legionella bacteria in
the water tank. Switching on the electric heater to perform the
Antilegoionella mode takes place within an interval of the day
with night-time electricity tariff.
WARNING!
Only for NHPC-V4-2 (water heaters with heat exchanger): The option "
Solar pump
adjust
" activates regulation of the solar pump's power depending on the differential
temperature. From this menu, the pump of the solar plant can be run for test by selecting the
power at which the pump is to be tested: 0-off, P1- reduced power and P2-maximum powerIf no
other settings are made, when the pump is activated it
will operate for 5 minutes, then the screen will close
automatically and the pump will switch to normal
automatic control
Reinstalling WiFi Network -
This menu is used when a WiFi
Internet Connection Module is available for initial configuration
or if necessary to change the WiFi network parameters. By
pressing the Enter button, the module will switch to the Access
30