below the visible part of the screen, there will be a down arrow. If there are more rows above the
visible part of the screen, there will be an arrow pointing upwards.
Settings display with parameter change -
After entering this screen, a blue marker frame is
displayed on the first parameter. You can use the arrows to position the marker frame on the
parameter you want to edit.
Then, pressing the Enter button enters the edit mode for this parameter. Then the blue frame
becomes red, indicating that the parameter can be changed with the up and down buttons. Pressing
Enter again confirms the parameter change and exits the edit mode. If you want to edit another
parameter, you need to re-position it and then edit it by the same procedure.
When all the necessary adjustments to the parameters in the selected menu are made, pressing the
On-Off / Back button goes to the previous screen.
Setting display with selection field.
When any parameter requires only to be turned on or off, a
selection field is used. In order to change this field, it is sufficient for the marker frame to be
positioned on it. There, this frame becomes red and pressing the Enter button checks or unchecks
the selected parameter. When all the necessary adjustments to the parameters in the selected menu
are made, pressing the On-Off / Back button goes to the previous screen.
WARNING!
If you do not change anything for a longer period (between 20 seconds and 5 minutes
depending on the setup menu), it will automatically exit the selected menu without saving the settings
made in this menu. The only exception is "
Temperature Setup
" menu, where changes made are
saved!
WORKING WITH THE CONTROLLER
General information
The controller is managed by easy and intuitive software specifically designed to automate boiler
management.
When the water heater is switched on, he selects by itself the most suitable heat source. Priority is
given to using the solar collector (NHPC-V4-2 only) and the heat pump. The electric heater will only
be used if the heat pump is deactivated or if the set temperature is above the heating capabilities of
the heat pump. It will also be switched on if "
Enhanced Heating
" mode is used.
If the differential temperature associated with the solar collector
Dt1 = t3 - t1
is greater than the
threshold set in the “
Pump
Control”
menu, item "
Solar Dt1
", column "
On
", the solar collector
circulation pump will be switched on in order to transfer its heat to the water heater. When the solar
pump is switched on but the differential temperature Dt1 drops below the threshold set on the same
row in the "
Off
" column, the pump will shut off.