1-
Timer status for additional heating with electric heater. If this option is enabled, the next time the
heater will be switched on or off is displayed;
2-
Temperature up to which the boiler will be heated;
3-
Consumption of electricity at daily tariff;
4-
Sign for hot water consumption during the day;
5-
Anode
protector condition;
6-
Consumption of electricity at night tariff;
7-
Date and time of the last reset of the
information for electricity consumption
By holding the Enter button for more than 2 seconds, the day and night electricity consumption
readings are reset. It also remembers the date and time of this reset, thus giving information about for
what period is the accumulated consumed electricity.
Heat pump
- From the screen “Information”, by pressing the down arrow you switch to the display of
important measured parameters from the module in the outdoor unit of the heat pump.
1
-Compressor outlet temperature;
2-
Compressor inlet temperature;
3-
Position of EEV;
4-
Supply
voltage;
5-
Current;
6-
Power Consumption;
7-
Evaporator temperature;
8-
External ambient
temperature;
9-
Heat pump condition;
10-
Compressor condition;
11-
Fan condition;
12-
Condition of 4-
way valve
The values of all parameters are updated in real time. If the compressor, fan, or 4-way valve works, it
will be marked in the appropriate place.
If there is no connection to the outdoor unit, there will be a
message "
No Heat pump
".
WiFi connectivity
- Internet connection status. From the
screen "Heat Pump", pressing the down arrow switches to a
screen with the communication information of the module with
the Internet
The fields are as follows:
ID –
Unique identifier for each modem.
IP –
Modem IP address
WiFi -
Modem status:
Idle
– The modem has not yet connected to a WiFi
router with Innernet
Access point – the modem is in mode “
Access point”
and
provides the ability to accept SSID and password on the
local WiFi network to connect to it
AP Associated –
the modem has been connected to
the router
Internet Access –
there is Internet access
Connected
– The modem has been connected to the
information system server
21